NSN 6685-00-063-7842

Part Details | DIAL INDICATING DIFFERENTIAL GAGE

6685-00-063-7842 An instrument designed to measure air, gas, fluid, and vapor differential by means of a pressure sensitive element(s) which transmits energy, by direct linkage, to the indicating pointer of a scale calibrated to units of pressure. The scale may indicate in units of pressure, quantity, or flow.

Alternate Parts: 227FB01125P7B, 07ACXXXXXXXE4CXXXX01, 6685-00-063-7842, 00-063-7842, 6685000637842, 000637842

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JUN 22, 196700-063-784262209 ( GAGE, DIFFERENTIAL, DIAL INDICATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-063-7842
Part Number Cage Code Manufacturer
227FB01125P7B05991CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS
07ACXXXXXXXE4CXXXX0105991CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS
Technical Data | NSN 6685-00-063-7842
Characteristic Specifications
ACTUATION TYPE BELLOWS
ACTUATING ELEMENT MATERIAL BERYLLIUM COPPER
SCALE TYPE SINGLE
SCALE NAME DIFFERENTIAL PRESSURE
POINTER COLOR WHITE
CONNECTOR TYPE VENT NOT PROVIDED
SCALE ACCURACY1/2 PCT OF FULL RANGE
SCALE INSCRIPTION/BACKGROUND COLORWHITE FIGURES,BLACK BACKGROUND
DIAL SIZE6 IN. DIA
POINTER TYPE INDICATING
ADJUSTABILITY ADJUSTABLE
CASE MATERIAL BRASS, FORGED
OVERALL DIAMETER7.500 INCHES NOMINAL
OVERALL DEPTH6.250 INCHES NOMINAL
PROTECTIVE CRYSTAL MATERIAL GLASS
CONNECTION QUANTITY4
CONNECTION TYPE INTERNAL
CONNECTION LOCATIONBD ANY ACCEPTABLE AND B ANY ACCEPTABLE
CONNECTION SIZE0.438 IN. NPT DIA
MOUNTING METHODBC ANY ACCEPTABLE AND ED ANY ACCEPTABLE