NSN 6680-01-012-0997

Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER

6680-01-012-0997 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: 10BCXXX0X70A5BBAXX01, 6680-01-012-0997, 01-012-0997, 6680010120997, 010120997

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66NOV 05, 197501-012-099708249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-012-0997
Part Number Cage Code Manufacturer
10BCXXX0X70A5BBAXX0105991CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS
Technical Data | NSN 6680-01-012-0997
Characteristic Specifications
MEDIA FOR WHICH DESIGNED WATER
PRESSURE TYPEK$J
MAXIMUM DIFFERENTIAL PRESSURE70.0 IN. OF WATER COLUMN
SCALE PRESENTATION RANGE0 TO 70 RANGE OF NUMERICAL MARKINGS
SCALE INSCRIPTION/BACKGROUND COLORBLACK MARKINGS ON WHITE BACKGROUND
TOTALIZING INTEGRATOR REGISTER NOT INCLUDED
CASE MATERIAL ALUMINUM, CAST
CASE SHAPE ROUND
MOUNTING TYPE ANY ACCEPTABLE
DEPTH4.219 INCHES NOMINAL
DIAMETER4.406 INCHES NOMINAL
INLET CONNECTION SIZE7/16 IN. 20 THD UNF
OUTLET CONNECTION SIZE7/16 IN. 20 THD UNF
ACCESSORY COMPONENTS AND QUANTITY2.000 IN. BERYLLIUM COPPER SENSOR W/COPPER-NICKEL HOUSING,1
SPECIAL FEATURES3-1/2 IN. DIA DIAL,DUAL SWITCH AND RED SET POINTER
CRITICALITY CODE JUSTIFICATIONACPYY$$AFEAT