Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-00-958-1947 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 16ABXXX0200A5BXXXX01, 347C085H01, 347C085H01, 6680-00-958-1947, 00-958-1947, 6680009581947, 009581947
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JAN 01, 1962 | 00-958-1947 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-958-1947
Part Number | Cage Code | Manufacturer |
---|---|---|
16ABXXX0200A5BXXXX01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
347C085H01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
347C085H01 | 79500 | WESTINGHOUSE ELECTRIC CORP |
Technical Data | NSN 6680-00-958-1947
Characteristic | Specifications |
---|---|
MEDIA FOR WHICH DESIGNED | WATER |
PRESSURE TYPE | HIGH |
MAXIMUM DIFFERENTIAL PRESSURE | 200 IN. WATER COLUMN |
CAPACITY RATING | 100 GPM |
SCALE PRESENTATION RANGE | 0 TO 100 RANGE OF NUMERICAL MARKINGS |
SMALLEST INCREMENT INDICATED | 1.000 |
SCALE INSCRIPTION/BACKGROUND COLOR | BLACK MARKINGS ON WHITE BACKGROUND |
TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
CASE MATERIAL | BRASS |
CASE SHAPE | ROUND |
MOUNTING TYPE | DC ANY ACCEPTABLE |
DEPTH | 4.375 INCHES NOMINAL |
DIAMETER | 7.500 INCHES NOMINAL |
INLET CONNECTION SIZE | 1/4 IN. -18 THD NPT |
OUTLET CONNECTION SIZE | 1/4 IN. -18 THD NPT |
ACCESSORY COMPONENTS AND QUANTITY | ELECTRICAL SWITCH 1 |