NSN 6680-00-813-5529
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-00-813-5529 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 227, 07ABXXX0150A5AXXXX01, 342C741H01, 342C741H01, 6680-00-813-5529, 00-813-5529, 6680008135529, 008135529
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JAN 01, 1962 | 00-813-5529 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-813-5529
Part Number | Cage Code | Manufacturer |
---|---|---|
227 | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
07ABXXX0150A5AXXXX01 | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
342C741H01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
342C741H01 | 79500 | WESTINGHOUSE ELECTRIC CORP |
Technical Data | NSN 6680-00-813-5529
Characteristic | Specifications |
---|---|
MEDIA FOR WHICH DESIGNED | WATER |
PRESSURE TYPE | J$K |
MAXIMUM DIFFERENTIAL PRESSURE | 150 IN. OF WATER |
CAPACITY RATING | 250 GPM |
SCALE PRESENTATION RANGE | 0 TO 250 RANGE OF NUMERICAL MARKINGS |
SMALLEST INCREMENT INDICATED | 250.000 |
SCALE INSCRIPTION/BACKGROUND COLOR | WHITE MARKINGS ON BLACK BACKGROUND |
TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
CASE MATERIAL | ALUMINUM |
CASE SHAPE | ROUND |
MOUNTING TYPE | D ANY ACCEPTABLE |
DEPTH | 6.380 INCHES NOMINAL |
DIAMETER | 7.500 INCHES NOMINAL |
INLET CONNECTION SIZE | 1/4 IN. NPT |
OUTLET CONNECTION SIZE | 1/4 IN. NPT |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY MEDIA FOR WHICH DESIGNED,PRESSURE TYPE,MAXIMUM DIFFERENTIAL PRESSURE,CAPACITY RATING,SCALE PRESENTATION RANGE,SMALLEST INCREMENT INDICATED,SCALE INSCRIPTION/BACKGROUND COLOR,INLET CONNECTION SIZE AND OUTLET CONNECTION SIZE |