NSN 6680-00-691-6093
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-00-691-6093 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: D601PC63, 6680-00-691-6093, 00-691-6093, 6680006916093, 006916093
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JAN 01, 1961 | 00-691-6093 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-691-6093
Part Number | Cage Code | Manufacturer |
---|---|---|
D601PC63 | 88939 | PHILPOT R D INDUSTRIES INSTRUMENTDIV |
Technical Data | NSN 6680-00-691-6093
Characteristic | Specifications |
---|---|
MEDIA FOR WHICH DESIGNED | WATER, SALT |
PRESSURE TYPE | MEDIUM |
SCALE PRESENTATION RANGE | 0 TO 85 PSI RANGE OF NUMERICAL MARKINGS |
SMALLEST INCREMENT INDICATED | 1.000 |
SCALE INSCRIPTION/BACKGROUND COLOR | BLACK MARKINGS ON WHITE BACKGROUND |
TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
CASE MATERIAL | BRONZE |
CASE SHAPE | RECTANGULAR |
MOUNTING TYPE | D ANY ACCEPTABLE |
DEPTH | 3.969 INCHES NOMINAL |
HEIGHT | 5.125 INCHES NOMINAL |
WIDTH | 4.375 INCHES NOMINAL |
INLET CONNECTION SIZE | 1/4 IN. 18 THD NPT |
OUTLET CONNECTION SIZE | 1/4 IN. 18 THD NPT |