NSN 6680-00-601-8113

Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER

6680-00-601-8113 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: 22602GPM, 226-0-2GPM, 8522165, 6680-00-601-8113, 00-601-8113, 6680006018113, 006018113

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 01, 196300-601-811308249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-601-8113
Part Number Cage Code Manufacturer
226-0-2GPM26126BURTON MEDICAL PRODUCTS CORPORATION
852216518876U S ARMY AVIATION AND MISSILECOMMAND
Technical Data | NSN 6680-00-601-8113
Characteristic Specifications
MEDIA FOR WHICH DESIGNED 0IL
PRESSURE TYPEK$J
MAXIMUM DIFFERENTIAL PRESSURE100.0 GPM FOR OIL
SCALE PRESENTATION RANGE0 TO 2 RANGE OF NUMERICAL MARKINGS
TOTALIZING INTEGRATOR REGISTER NOT INCLUDED
CASE MATERIAL STEEL
CASE SHAPE RECTANGULAR
MOUNTING TYPED ANY ACCEPTABLE
DEPTH3.875 INCHES NOMINAL
LENGTH4.125 INCHES NOMINAL
WIDTH3.250 INCHES NOMINAL
SPECIAL FEATURESITT BARTON INSTRUMENTS MODEL NO. 226