NSN 6680-00-470-4783
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-00-470-4783 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 06SCXXX0100E1BXXXX01, 06SCXXX0100E1BXXXC01, 6680-00-470-4783, 00-470-4783, 6680004704783, 004704783
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | AUG 19, 1970 | 00-470-4783 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-470-4783
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 06SCXXX0100E1BXXXX01 | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
| 06SCXXX0100E1BXXXC01 | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
Technical Data | NSN 6680-00-470-4783
| Characteristic | Specifications |
|---|---|
| MEDIA FOR WHICH DESIGNED | LIQUID |
| PRESSURE TYPE | K$J |
| MAXIMUM DIFFERENTIAL PRESSURE | 100.0 PSI |
| SCALE PRESENTATION RANGE | 0 TO 100 RANGE OF NUMERICAL MARKINGS |
| SCALE INSCRIPTION/BACKGROUND COLOR | BLACK MARKINGS ON WHITE BACKGROUND |
| TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
| CASE MATERIAL | ALUMINUM, CAST |
| CASE SHAPE | ROUND |
| MOUNTING TYPE | D ANY ACCEPTABLE |
| DEPTH | 4.656 INCHES NOMINAL |
| DIAMETER | 3.141 INCHES NOMINAL |
| INLET CONNECTION SIZE | 7/16 IN. 20 THD UNF |
| OUTLET CONNECTION SIZE | 7/16 IN. 20 THD UNF |
| ACCESSORY COMPONENTS AND QUANTITY | 2.000 IN. CRES SENSOR AND HOUSING,1 |
| SPECIAL FEATURES | 3.000 IN. DIA DIAL |
| CRITICALITY CODE JUSTIFICATION | ACPYY$$AFEAT |