NSN 6680-00-457-8688
Part Details | FLOW RATE INDICATING METER
6680-00-457-8688 An instrument for measuring the rate of flow of a fluid through a pipeline. This measurement is indicated on a graduated scale either by means of a float confined in a tube, or pointer connected to a vane, or piston and spring or the like. Excludes METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 5208, 520-8, VFA8EC, VFA-8-EC, 8805, 8773, 6680-00-457-8688, 00-457-8688, 6680004578688, 004578688
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | APR 30, 1969 | 00-457-8688 | 38346 ( METER, FLOW RATE INDICATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-457-8688
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 520-8 | 85274 | DWYER INSTRUMENTS INCDBA PROXIMITY CONTROLS |
| VFA-8-EC | 85274 | DWYER INSTRUMENTS INCDBA PROXIMITY CONTROLS |
| 8805 | 06178 | PUREGAS LLC |
| 8773 | 06178 | PUREGAS LLC |
Technical Data | NSN 6680-00-457-8688
| Characteristic | Specifications |
|---|---|
| DESIGN TYPE | CASE |
| SCALE QUANTITY | 1 |
| DIAL SCALE MARKING RANGE | P10.0/P100.0 |
| DIAL SCALE REFERENCE POINTER | NOT INCLUDED |
| METER TYPE | FLOAT |
| OVERALL LENGTH | 4.188 INCHES NOMINAL |
| INTEGRAL PULSATION DAMPENER | NOT INCLUDED |
| INLET CONNECTION TYPE | THREADED |
| INLET CONNECTION POSITION FOR WHICH DESIGNED | HORIZONTAL |
| OUTLET CONNECTION TYPE | THREADED |
| OUTLET CONNECTION POSITION FOR WHICH DESIGNED | HORIZONTAL |
| INTEGRAL RELIEF VALVE | NOT INCLUDED |
| INTEGRAL HEAT SOURCE | NOT INCLUDED |
| ALARM SIGNAL | NOT INCLUDED |
| CONSTRUCTION | HK ANY ACCEPTABLE |
| BASE | NOT INCLUDED |
| CARRYING HANDLE | NOT INCLUDED |
| METERING TUBE QUANTITY | 1 |
| TUBE MATERIAL | PLASTIC |
| SCALE TYPE | DIRECT CAPACITY READING |
| MEDIA FOR WHICH DESIGNED | AIR |
| SCALE MARKING | SCFH AIR |
| FLOAT QUANTITY | 1 |
| FLOAT MATERIAL | GLASS |
| SPINNING FLOAT | NOT INCLUDED |
| FLOAT TYPE | GUIDED |
| GUIDE TYPE | |
| UNIT TYPE | MOUNTED |
| MOUNTING METHOD | SURFACE PANEL |
| INLET CONNECTION SIZE | 0.125 IN. NPT |
| INLET CONNECTION DEVICE TYPE | STATIONARY |
| OUTLET CONNECTION SIZE | 0.125 IN. NPT |
| OUTLET CONNECTION DEVICE TYPE | STATIONARY |
| MAXIMUM WORKING PRESSURE | 100.0 POUNDS PER SQUARE INCH |