NSN 6680-00-069-4989
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-00-069-4989 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 226A080P4IR, D601PC22, 6680-00-069-4989, 00-069-4989, 6680000694989, 000694989
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JAN 01, 1961 | 00-069-4989 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-069-4989
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 226A080P4IR | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
| D601PC22 | 88939 | PHILPOT R D INDUSTRIES INSTRUMENTDIV |
Technical Data | NSN 6680-00-069-4989
| Characteristic | Specifications |
|---|---|
| MEDIA FOR WHICH DESIGNED | WATER, FRESH |
| PRESSURE TYPE | MEDIUM |
| MAXIMUM DIFFERENTIAL PRESSURE | 61 PSI MIN TO 200 PSI,MAX |
| SCALE PRESENTATION RANGE | 0 TO 80 PSI RANGE OF NUMERICAL MARKINGS FOR FRESH WATER |
| SMALLEST INCREMENT INDICATED | 1.000 |
| SCALE INSCRIPTION/BACKGROUND COLOR | BLACK MARKINGS ON WHITE BACKGROUND |
| TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
| CASE MATERIAL | BRONZE |
| CASE SHAPE | RECTANGULAR |
| MOUNTING TYPE | D ANY ACCEPTABLE |
| DEPTH | 3.891 INCHES NOMINAL |
| HEIGHT | 3.500 INCHES NOMINAL |
| WIDTH | 4.375 INCHES NOMINAL |
| INLET CONNECTION SIZE | 1/4 IN.-18 THD NPT |
| OUTLET CONNECTION SIZE | 1/4 IN.-18 THD NPT |
| END ITEM IDENTIFICATION | POSEIDON |