NSN 6625-00-127-0079
Part Details | OSCILLOSCOPE
6625-00-127-0079 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.
Alternate Parts: 5L.7433.001.02, OS261U, OS-261/U, 475, 6625-00-127-0079, 00-127-0079, 6625001270079, 001270079
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JAN 06, 1973 | 00-127-0079 | 00357 ( OSCILLOSCOPE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-127-0079
Part Number | Cage Code | Manufacturer |
---|---|---|
5L.7433.001.02 | D1901 | HENSOLDT SENSORS GMBHDIV SEPS |
OS-261/U | 80058 | JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM |
475 | 80009 | TEKTRONIX, INC.DBA TEKTRONIX |
Technical Data | NSN 6625-00-127-0079
Characteristic | Specifications |
---|---|
SCREEN SIZE | 8.000 BY 10.000 CM |
BEAM QUANTITY | 2 |
SWEEP CIRCUITS | INCLUDED |
SWEEP CIRCUIT TYPE | D ANY ACCEPTABLE |
SWEEP FREQUENCY RANGE | +0.0 TO +200.0 MEGAHERTZ |
AMPLIFIER DEFLECTION SENSITIVITY PROVISION | PROVIDED |
VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING | -2.0 MILLIVOLTS MINIMUM AND -5.0 VOLTS MAXIMUM |
HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING | -2.0 MILLIVOLTS MINIMUM AND -5.0 VOLTS MAXIMUM |
FREQUENCY RESPONSE RATING | PROVIDED |
X-AXIS FREQUENCY RESPONSE RATING | 0.0 MEGAHERTZ MINIMUM AND 1.0 MEGAHERTZ MAXIMUM |
Y-AXIS FREQUENCY RESPONSE RATING | 0.0 MEGAHERTZ MINIMUM AND 1.0 MEGAHERTZ MAXIMUM |
Z-AXIS FREQUENCY RESPONSE RATING | 0.0 MEGAHERTZ MINIMUM AND 50.0 MEGAHERTZ MAXIMUM |
AMPLIFIER INPUT IMPEDANCE RATING PROVISION | PROVIDED |
X-AXIS INPUT IMPEDANCE RATING | 1.0 MEGOHMS NOMINAL |
Y-AXIS INPUT IMPEDANCE RATING | 1.0 MEGOHMS NOMINAL |
AMPLITUDE CALIBRATING VOLTAGE WAVEFORM | ANY ACCEPTABLE |
CALIBRATING PEAK TO PEAK AMPLITUDE | 300.0 MILLIVOLTS NOMINAL |
ACCURACY RANGE IN PERCENT | M1.0/P1.0 |
CALIBRATED SCREEN SCALE | INCLUDED |
GRADUATION INTERVAL | GRADUATED IN V/0.2 CM BOTH AXIS |
CAMERA RECORDING DEVICE ACCOMMODATION | PROVIDED |
CURRENT TYPE | AC |
VOLTAGE RATING | 110.0 VOLTS NOMINAL AND 115.0 VOLTS NOMINAL AND 120.0 VOLTS NOMINAL AND 220.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL AND 240.0 VOLTS NOMINAL |
FREQUENCY RATING | 48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM |
PHASE | SINGLE |
OVERALL LENGTH | 20.300 INCHES NOMINAL |
OVERALL WIDTH | 12.900 INCHES NOMINAL |
OVERALL HEIGHT | 6.200 INCHES NOMINAL |
MOUNTING METHOD | TABLE |
ACCESSORY COMPONENTS AND QUANTITY | ACCESSORY POUCH 1; LIGHT FILTER 2; PROBE 2 |