NSN 6625-00-113-5954

Part Details | MULTIPLE SCALE METER

6625-00-113-5954 An instrument with two or more different scales measuring different quantities, usually on a single calibrated dial or digital readout display. It is intended for visually monitoring an operation. The meter must be permanently connected into an appropriate electronic circuit. Excludes: AMMETER; VOLTMETER; WATTMETER and METER, ELECTRICAL FREQUENCY.

Alternate Parts: 2496, 6625-00-113-5954, 00-113-5954, 6625001135954, 001135954

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66SEP 04, 196800-113-595462222 ( METER, MULTIPLE SCALE )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR FLUSH MTG

Cross Reference | NSN 6625-00-113-5954
Part Number Cage Code Manufacturer
249611332GENERAL MICROWAVE CORPORATION
Technical Data | NSN 6625-00-113-5954
Characteristic Specifications
INSTALLATION DESIGN PANEL
INDICATOR TYPE DIAL W/POINTER
MOVEMENT TYPE MOVING COIL, PERMANENT MAGNET
MOVEMENT SUSPENSION METHOD JEWEL PIVOT BASE
CIRCUIT ATTACHMENT METHOD AND QUANTITY2 THREADED STUD
SENSITIVITY RATING1.0 MILLIAMPERES
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED DC
STYLE DESIGNATOR RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE2.750 INCHES NOMINAL
METER DEPTH BEHIND MOUNTING FLANGE0.797 INCHES NOMINAL
OVERALL HEIGHT4.062 INCHES NOMINAL
OVERALL LENGTH2.234 INCHES NOMINAL
OVERALL WIDTH4.531 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
MOUNTING STUD DIAMETER0.138 INCHES NOMINAL
MOUNTING STUD LENGTH0.390 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.531 INCHES NOMINAL
MATERIAL PLASTIC
NUCLEAR HARDNESS CRITICAL FEATURE
ENVIRONMENTAL PROTECTION SHOCK RESISTANT AND VIBRATION RESISTANT
FURNISHED ITEMS AND QUANTITYNUT 2
FEATURES PROVIDED ZERO ADJUSTER
SPECIAL FEATURESRUGGEDIZED
FSC APPLICATION DATATEST SET,ELECT. EQUIP.