NSN 6625-00-081-0126

Part Details | VOLTMETER

6625-00-081-0126 An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

Alternate Parts: 50100021RXRX, 50-100021RXRX, AB18, 8AB18VAM, MR49W300ACVVH, MILM160343, MIL-M-16034-3, MR49W300ACVV, 6625-00-081-0126, 00-081-0126, 6625000810126, 000810126

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 01, 196300-081-012616449 ( VOLTMETER )
REFERENCE DRAWINGS & PICTURES

FOUR HOLE/STUD RECTANGULAR/SQUARE

RECTANGULAR FLUSH MTG

Cross Reference | NSN 6625-00-081-0126
Part Number Cage Code Manufacturer
50-100021RXRX29834GENERAL ELECTRIC COINSTRUMENT PRODUCTS SECTION
AB1803516GENERAL ELECTRIC COMETER BUSINESS DEPT
8AB18VAM03516GENERAL ELECTRIC COMETER BUSINESS DEPT
MR49W300ACVVH6Z382HUGHES CORPORATIONDBA WESCHLER INSTRUMENTS
MIL-M-16034-381349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MR49W300ACVV81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 6625-00-081-0126
Characteristic Specifications
INSTALLATION DESIGN PANEL
INDICATOR TYPE DIAL W/POINTER
MOVEMENT TYPE MOVING IRON VANE
MOVEMENT SUSPENSION METHOD JEWEL PIVOT BASE
CIRCUIT ATTACHMENT METHOD AND QUANTITY2 THREADED STUD
SENSITIVITY RATING10.0 VOLT-AMPERES
SCALE SELECTION METHOD TERMINAL
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS2600.0
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED AC
FREQUENCY RATING60.0 HERTZ NOMINAL
PHASE SINGLE
STYLE DESIGNATOR RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE3.980 INCHES MAXIMUM
METER DEPTH BEHIND MOUNTING FLANGE9.000 INCHES MAXIMUM
OVERALL HEIGHT4.250 INCHES MINIMUM AND 4.750 INCHES MAXIMUM
OVERALL LENGTH11.000 INCHES MAXIMUM
OVERALL WIDTH4.250 INCHES MINIMUM AND 4.750 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
MOUNTING STUD DIAMETER0.250 INCHES NOMINAL
MOUNTING STUD LENGTH0.625 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLE FOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.376 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.376 INCHES NOMINAL
MATERIAL0$DSTB000
SURFACE TREATMENT PAINT
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
ENVIRONMENTAL PROTECTION DUST RESISTANT AND HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
FURNISHED ITEMS AND QUANTITYMTG HDW 4; TERM. HDW 2
FEATURES PROVIDED ELECTRICAL OVERLOAD PROTECTION AND MAGNETIC SHIELD AND ZERO ADJUSTER
SPECIAL FEATURESRUGGEDIZED
TEST DATA DOCUMENT81349-MIL-M-16034 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-M-16034 TO 3 GOVERNMENT SPECIFICATION
SUPPLEMENTARY FEATURESRESISTS FRICTION EFFECTS
FSC APPLICATION DATATEST SET,ELECT. EQUIP.