NSN 6625-00-005-5416

Part Details | NULL METER

6625-00-005-5416 An electrically operated instrument having a zero point on its scale (usually located in the center thereof). It may not indicate units of electrical measurement. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. When the indication shows zero, an electrical value of "zero" has been reached in the circuit. It is generally used in situations in which zero is the desired effect. Excludes AMMETER, GALVANOMETER; METER, ARBITARY SCALE; and VOLTMETER.

Alternate Parts: K2001 12, K2001 1-2, 766474REVA, 2661195, 8069639, 80696-39, 6625-00-005-5416, 00-005-5416, 6625000055416, 000055416

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JUN 16, 197200-005-541661382 ( METER, NULL )
REFERENCE DRAWINGS & PICTURES

FOUR HOLE/STUD RECTANGULAR/SQUARE

RECTANGULAR FLUSH MTG

Cross Reference | NSN 6625-00-005-5416
Part Number Cage Code Manufacturer
K2001 1-255469ESSEX INDUSTRIES, INC.
766474REVA56232LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
266119510001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
80696-3960741TRIPLETT BLUFFTON CORPORATIONDBA LFE INSTRUMENTS
Technical Data | NSN 6625-00-005-5416
Characteristic Specifications
INSTALLATION DESIGN PANEL
INDICATOR TYPE DIAL W/POINTER
SCALE MARKINGRPM; M 25; M 15; M 5; 0; 5; 15; 25
MOVEMENT TYPE MOVING IRON VANE
MOVEMENT SUSPENSION METHOD METAL PIVOT BASE
CIRCUIT ATTACHMENT METHOD AND QUANTITY2 THREADED STUD
SENSITIVITY RATING5000.0 MILLIVOLTS
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS3250.0
CIRCUIT CURRENT FOR WHICH DESIGNED DC
STYLE DESIGNATOR RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE2.220 INCHES NOMINAL
METER DEPTH BEHIND MOUNTING FLANGE1.390 INCHES NOMINAL
OVERALL HEIGHT2.390 INCHES NOMINAL
OVERALL LENGTH2.822 INCHES MAXIMUM
OVERALL WIDTH2.770 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
MOUNTING STUD DIAMETER0.112 INCHES NOMINAL
MOUNTING STUD LENGTH0.730 INCHES MAXIMUM
MOUNTING ARRANGEMENT STYLE FOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.880 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.880 INCHES NOMINAL
MATERIAL PLASTIC
SURFACE TREATMENT ANODIZE
NUCLEAR HARDNESS CRITICAL FEATURE
FURNISHED ITEMS AND QUANTITYTWO WASHERS AND NUTS FOR MTG
FEATURES PROVIDED ELECTRICAL OVERLOAD PROTECTION AND ZERO ADJUSTER
FSC APPLICATION DATATEST SET,ELECT. EQUIP.