NSN 6340-00-257-5127
Part Details | FIRE DETECTOR SYSTEM SENSING ELEMENT
6340-00-257-5127 An item consisting of a pair of electrical conductors imbedded in a semiconductor material, having a negative temperature coefficient of resistance which is tightly encased in a suitable metallic tube. The ends of the assembly are terminated for adaption in a fire detector system.
Alternate Parts: 355812255, 35581-2-255, CH001289081, CH00128-9-081, 6340-00-257-5127, 00-257-5127, 6340002575127, 002575127
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
63 | MAR 19, 1971 | 00-257-5127 | 20919 ( SENSING ELEMENT, FIRE DETECTOR SYSTEM ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6340-00-257-5127
Part Number | Cage Code | Manufacturer |
---|---|---|
35581-2-255 | 73168 | KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS |
CH00128-9-081 | 81755 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN AERONAUTICS |
Technical Data | NSN 6340-00-257-5127
Characteristic | Specifications |
---|---|
ELEMENT LENGTH | 81.000 FEET NOMINAL |
FIRE ALARM MINIMUM TEMP SETTING | 255.0 DEG FAHRENHEIT |
TEMP SETTING TOLERANCE | 50.0 DEG FAHRENHEIT NOMINAL |
TERMINATION QUANTITY | 2 |
TERMINATION CONTROLLING AGENCY | FENWAL INC DIV OF KIDDE |
TERMINATION TYPE | CONNECTOR PLUG |
TERMINATION IDENTIFICATION | PART NO. MS24266R14B7 |