NSN 6130-01-240-1178
Part Details | POWER SUPPLY
6130-01-240-1178 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.
Alternate Parts: HA150.5, HA15-0.5, 9387300, 6130-01-240-1178, 01-240-1178, 6130012401178, 012401178
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | SEP 10, 1986 | 01-240-1178 | 00740 ( POWER SUPPLY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6130-01-240-1178
Part Number | Cage Code | Manufacturer |
---|---|---|
HA15-0.5 | 54470 | DEPT OF THE AIR FORCEHQ AIR DEFENSE WEAPONS CENTER /ADC/ |
9387300 | 19200 | US ARMY ARDEC RDECOM |
Technical Data | NSN 6130-01-240-1178
Characteristic | Specifications |
---|---|
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
OVERALL LENGTH | 4.870 INCHES NOMINAL |
OVERALL WIDTH | 4.000 INCHES NOMINAL |
OVERALL HEIGHT | 1.620 INCHES NOMINAL |
SPECIAL FEATURES | LINE REGULATION=+ OR - 0.05 PERCENT FOR A 10 PERCENT LINE CHANGE; + OR - 0.05 PERCENT FOR A 50 PERCENT LOAD CHANGE; OUTPUT RIPPLE=2V TO 15V UNITS,5.0MV PK-PK MAX.,20V TO 200V UNITS,0.02PERCENT PK-PK MAX.; TRANSIENT RESPONSE=50 SEC. FOR A 50 PERCENT LOAD CHANGE;SHORT CIRCUIT AND OVERLOAD PROTECTION=AUTOMATIC CURRENT LIMIT/FOLDBACK; REMOTE SENSING=OPEN SENSE LEAD PROTECTION BUILT-IN; STABILITY=+0.3 PERCENT FOR 24 HR. PERIOD AFTER 1HR. WARM-UP; TEMP.RATING=0 TO 50 DEG. C. FULL-RATED,DERATED LINEARLY TO 40 PERCENT AT 70 DEG. C.; TEMP. COEFFICIENT=+ OR - 0.03 PERCENT/DEG. C. MAX.; EFFICIENCY=5V UNITS ARE 45 PERCENT,12V AND 15V UNITS ARE 55 PERCENT,20V AND 24V ARE 60 PERCENT |