NSN 6130-01-240-1177

Part Details | POWER SUPPLY

6130-01-240-1177 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.

Alternate Parts: HD126.8, HD12-6.8, HD126.8A, HD12-6.8-A, 9387301, 6130-01-240-1177, 01-240-1177, 6130012401177, 012401177

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61SEP 10, 198601-240-117700740 ( POWER SUPPLY )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6130-01-240-1177
Part Number Cage Code Manufacturer
HD12-6.854470DEPT OF THE AIR FORCEHQ AIR DEFENSE WEAPONS CENTER /ADC/
HD12-6.8-A54407POWER-ONE DC POWER SUPPLIES
938730119200US ARMY ARDEC RDECOM
Technical Data | NSN 6130-01-240-1177
Characteristic Specifications
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
OVERALL LENGTH9.000 INCHES NOMINAL
OVERALL WIDTH4.870 INCHES NOMINAL
OVERALL HEIGHT2.750 INCHES NOMINAL
SPECIAL FEATURESLINE REGULATION=+ OR - 0.05 PERCENT FOR A 10 PERCENT LINE CHANGE; LOAD REGULATION=+ OR - 0.05 PERCENT FOR A 50 PERCENT LOAD CHANGE; OUTPUT RIPPLE=2V-15V UNITS ARE 5.0MV PK-PK MAX.,20V-200V UNITS ARE 0.02 PERCENT PK-PK MAX.;TRANSIENT RESPONSE=50 SEC. FOR A 50 PERCENT LOAD CHANGE; SHORT CIRCUIT AND OVERLOAD PROTECTION=AUTOMATIC CURRENT LIMIT/FOLDBACK; REMOTE SENSING=OPEN SENSE LEAD PROTECTION BUILT-IN; STABILITY=+0.3 PERCENT FOR 24 HR. PERIOD AFTER 1 HR. WARM-UP; TEMP. RATING=0-50 DEG. C. FULL-RATED,DERATED LINEARLY TO 40 PERCENT AT 70 DEG. C.; TEMP. COEFFICIENT=+ OR - 0.03 PERCENT/DEG. C. MAX.; EFFICIENCY=5V UNITS ARE 45 PERCENT,12V AND 15V UNITS ARE 55 PERCENT,20V AND 24V UNITS ARE 60 PERCENT