NSN 6130-01-212-2647

Part Details | POWER SUPPLY

6130-01-212-2647 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.

Alternate Parts: DC268, DC2-68, 10139836, 9850222B, 985022-2B, 10400882B, 1040-088-2B, 6130-01-212-2647, 01-212-2647, 6130012122647, 012122647

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61JUL 10, 198501-212-264700740 ( POWER SUPPLY )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6130-01-212-2647
Part Number Cage Code Manufacturer
DC2-6866015HDL RESEARCH LAB INC
10139836A486GNIMIKKEISTOKESKUS NCB FINLAND
985022-2B82577RAYTHEON COMPANYDBA RAYTHEON
1040-088-2B55196SORA POWER INC.DBA SIGMA DIVISION
Technical Data | NSN 6130-01-212-2647
Characteristic Specifications
RECTIFICATION METHOD SINGLE PHASE FULL WAVE CENTER TAP
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
ENVIRONMENTAL PROTECTION HERMETICALLY SEALED
MAXIMUM OPERATING ALTITUDE RATING70000.0 FEET
OVERALL LENGTH3.000 INCHES NOMINAL
OVERALL WIDTH2.500 INCHES NOMINAL
OVERALL HEIGHT0.800 INCHES MAXIMUM
OPERATING AMBIENT TEMP RANGE-54.0 TO +71.0 DEG CELSIUS