NSN 6130-01-049-6351
Part Details | METALLIC RECTIFIER
6130-01-049-6351 An electrical item (the working element of which is constructed essentially of metallic substances) which changes alternating current to direct current by the rectifying action occurring at the junction interface between a metallic conductor and a semiconductor. Excludes sets of metallic rectifiers which are not rated for rectifying capabilities but are used as suppressors. For items containing germanium or silicon, see SEMICONDUCTOR DEVICE (1), DIODE; SEMICONDUCTOR DEVICE SET and RECTIFIER, SEMICONDUCTOR DEVICE. For a complete power supply utilizing metallic rectifiers, see POWER SUPPLY.
Alternate Parts: S06CF12FC, RO0105, LO1105, S06CF12FC, S06CF12FC, 6130-01-049-6351, 01-049-6351, 6130010496351, 010496351
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | OCT 21, 1977 | 01-049-6351 | 00299 ( RECTIFIER, METALLIC ) |
REFERENCE DRAWINGS & PICTURES
HALF-WAVE 1 PHASE

HALF-WAVE 1 PHASE

Cross Reference | NSN 6130-01-049-6351
Part Number | Cage Code | Manufacturer |
---|---|---|
S06CF12FC | 59656 | DEAN TECHNOLOGY INC.DBA CKE |
RO0105 | 13873 | DLA AVIATION |
LO1105 | 16236 | DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL |
S06CF12FC | 59565 | QUALITY MFG COMPANY INC |
S06CF12FC | 01411 | WESTINGHOUSE ELECTRIC CORPMEDIUM AC MOTOR AND GEARING DIV |
Technical Data | NSN 6130-01-049-6351
Characteristic | Specifications |
---|---|
MATERIAL | SELENIUM |
CIRCUIT CONNECTION STYLE DESIGNATOR | HALF-WAVE 1 PHASE |
RMS INPUT MAXIMUM VOLTAGE RATING | 120.0 VOLTS |
DC OUTPUT MAXIMUM VOLTAGE RATING | 108.0 VOLTS NEW |
TERMINAL QUANTITY | 2 |
TERMINAL TYPE | SOLDER LUG |
GROUNDED TERMINAL | NOT INCLUDED |
SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO1105 |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | REFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NA VAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL, MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP. |
CRITICALITY CODE JUSTIFICATION | ZZZY |