6130-01-037-5035 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.

Alternate Parts: PM23.33.0A, PM-23.3-3.0A, 101861112, 10186111-2, 6130-01-037-5035, 01-037-5035, 6130010375035, 010375035

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61MAR 18, 197701-037-503500740 ( POWER SUPPLY )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6130-01-037-5035
Part Number Cage Code Manufacturer
PM-23.3-3.0A13850TECHNIPOWER LLCDBA UNIPOWER
10186111-218876U S ARMY AVIATION AND MISSILECOMMAND
Technical Data | NSN 6130-01-037-5035
Characteristic Specifications
RECTIFICATION METHOD SINGLE PHASE FULL WAVE CENTER TAP
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
ENVIRONMENTAL PROTECTION HERMETICALLY SEALED
OVERALL LENGTH7.501 INCHES MINIMUM AND 7.749 INCHES MAXIMUM
OVERALL WIDTH6.437 INCHES MINIMUM AND 6.562 INCHES MAXIMUM
OVERALL HEIGHT4.809 INCHES MINIMUM AND 4.934 INCHES MAXIMUM
FEATURES PROVIDED FILTER
SPECIAL FEATURESM29.0 TO 52.0 DEG C BASE OPERATING TEMP