NSN 6110-00-230-9180
Part Details | DISTRIBUTION BOX
6110-00-230-9180 An enclosure which includes mounts, and protects such items as switches, circuit breakers, jacks, fuseholders, connectors, terminals and/or terminal boards, resistors, capacitors, transformers, and the like. It is primarily designed to distribute electrical power from one or more primary power source(s) such as generator(s) and battery(ies) to one or more electrical and/or electronic item(s). It may include a cover or door. For enclosures which include only circuit breakers, switches, jacks, fuseholders, terminals and/or terminal boards, see CIRCUIT BREAKER BOX; SWITCH BOX; JACK BOX; FUSE BOX and TERMINAL BOX. For enclosure primarily designed to interconnect two or more electrical and/or electronic items, except primary power source(s) see INTERCONNECTING BOX. For empty boxes which are designed to mount, but do not include electrical devices such as switches, jacks, fuseholders, terminals and/or terminal boards, see JUNCTION BOX. See also INTERCONNECTING CABINET; CONTROL (as modified); PANEL (1) (as modified); RELAY ASSEMBLY; PANEL, POWER DISTRIBUTION; SWITCHBOARD (as modified) and PANEL, FUSE. Excludes CONNECTOR-SWITCH.
Alternate Parts: 646777, 6110-00-230-9180, 00-230-9180, 6110002309180, 002309180
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 01, 1963 | 00-230-9180 | 19735 ( DISTRIBUTION BOX ) |
REFERENCE DRAWINGS & PICTURES
4 POINT-RECTANGULAR
RECTANGULAR, SURFACE MOUNTING
Cross Reference | NSN 6110-00-230-9180
Part Number | Cage Code | Manufacturer |
---|---|---|
646777 | 56232 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
Technical Data | NSN 6110-00-230-9180
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | RECTANGULAR, SURFACE MOUNTING |
OVERALL DEPTH | 3.187 INCHES NOMINAL |
OVERALL HEIGHT | 19.594 INCHES NOMINAL |
OVERALL WIDTH | 4.250 INCHES NOMINAL |
MATERIAL | COPPER ALLOY |
SURFACE TREATMENT | ENAMEL |
ENTRANCE TYPE AND QUANTITY | 2 STUFFING BOX |
CABLE ENTRANCE DIAMETER | 1.062 INCHES NOMINAL AND 0.750 INCHES NOMINAL |
MOUNTING METHOD | UNTHREADED HOLE |
STANDARD MOUNTING PATTERN DESIGNATOR | 4 POINT-RECTANGULAR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.500 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 12.625 INCHES NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.406 INCHES NOMINAL |
FURNISHED ITEMS AND QUANTITY | 1 RHEOSTAT |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT-NEMA TYPE 4 |
FEATURES PROVIDED | COVER AND FUSE |