NSN 6110-00-179-3499

Part Details | DISTRIBUTION BOX

6110-00-179-3499 An enclosure which includes mounts, and protects such items as switches, circuit breakers, jacks, fuseholders, connectors, terminals and/or terminal boards, resistors, capacitors, transformers, and the like. It is primarily designed to distribute electrical power from one or more primary power source(s) such as generator(s) and battery(ies) to one or more electrical and/or electronic item(s). It may include a cover or door. For enclosures which include only circuit breakers, switches, jacks, fuseholders, terminals and/or terminal boards, see CIRCUIT BREAKER BOX; SWITCH BOX; JACK BOX; FUSE BOX and TERMINAL BOX. For enclosure primarily designed to interconnect two or more electrical and/or electronic items, except primary power source(s) see INTERCONNECTING BOX. For empty boxes which are designed to mount, but do not include electrical devices such as switches, jacks, fuseholders, terminals and/or terminal boards, see JUNCTION BOX. See also INTERCONNECTING CABINET; CONTROL (as modified); PANEL (1) (as modified); RELAY ASSEMBLY; PANEL, POWER DISTRIBUTION; SWITCHBOARD (as modified) and PANEL, FUSE. Excludes CONNECTOR-SWITCH.

Alternate Parts: 7970107, 6110-00-179-3499, 00-179-3499, 6110001793499, 001793499

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61JAN 17, 196900-179-349919735 ( DISTRIBUTION BOX )
REFERENCE DRAWINGS & PICTURES

4 POINT-RECTANGULAR

RECTANGULAR, SURFACE MOUNTING

Cross Reference | NSN 6110-00-179-3499
Part Number Cage Code Manufacturer
797010719207U S ARMY TANK AUTOMOTIVE COMMANDAMSTA-IM-MM
Technical Data | NSN 6110-00-179-3499
Characteristic Specifications
STYLE DESIGNATOR RECTANGULAR, SURFACE MOUNTING
OVERALL DEPTH3.093 INCHES NOMINAL
OVERALL HEIGHT12.625 INCHES NOMINAL
OVERALL WIDTH6.625 INCHES NOMINAL
MATERIAL ALUMINUM ALLOY
SURFACE TREATMENT ANODIZE
ENTRANCE TYPE AND QUANTITY4 PREPUNCHED HOLE AND 4 ELECTRICAL CONNECTOR
MOUNTING METHOD THREADED HOLE
STANDARD MOUNTING PATTERN DESIGNATOR 4 POINT-RECTANGULAR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH8.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT4.000 INCHES NOMINAL
MOUNTING FACILITY THREAD SIZE0.312-18 UNC
FURNISHED ITEMS AND QUANTITY1 TERMINAL BOARD
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION WATERTIGHT-NEMA TYPE 4
FEATURES PROVIDED COVER