NSN 5996-00-248-6436

Part Details | DIRECT CURRENT AMPLIFIER

5996-00-248-6436 An electronic device whose input signals control power from a source independent of the input signals and delivers output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It is used for small variations in direct current electrical impulses, and generally employs direct coupling between stages through resistors.

Alternate Parts: 193385, 193385, 5996-00-248-6436, 00-248-6436, 5996002486436, 002486436

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 15, 197300-248-643619692 ( AMPLIFIER, DIRECT CURRENT )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR OR SQUARE

Cross Reference | NSN 5996-00-248-6436
Part Number Cage Code Manufacturer
19338588177ROSEMOUNT ANALYTICAL INC
19338553110VIASYS RESPIRATORY CARE INC.DBA BIOSYS HEALTHCARE
Technical Data | NSN 5996-00-248-6436
Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
SIGNAL VOLTAGE RATING PER CHANNELB725.0 MILLIVOLTS MAXIMUM AND F5.0 VOLTS MAXIMUM
IMPEDANCE RATING PER CHANNEL10.000 GIGOHMS OPERATING CHANNEL
OPERATING CONTROL METHOD AUTOMATIC
CONTROL TYPE REMOTE
INDICATOR DEVICE TYPE AND QUANTITY1 AUDIBLE ALARM AND 1 METER
AVERAGE LIFE MEASUREMENT NOT RATED
OPERATING TEMP RANGE+32.0 TO +110.0 DEG FAHRENHEIT
EXTERNAL DC OPERATING VOLTAGE IN VOLTS15.0 NOMINAL SINGLE VOLTAGE
CONNECTION TYPE AND LOCATION PRINTED CIRCUIT RIGHT SIDE
CONNECTION CONTACT TYPE AND QUANTITY15 PRINTED CIRCUIT EXTERNAL
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN PANEL
BASIC SHAPE STYLE RECTANGULAR OR SQUARE