NSN 5985-00-973-2806

Part Details | ELECTRICAL DUMMY LOAD

5985-00-973-2806 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: SMB424028, SM-B-424028, SMB424028, SM-B-424028, SMB424028, SM-B-424028, 5985-00-973-2806, 00-973-2806, 5985009732806, 009732806

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196200-973-280600335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

COAXIAL MOUNTED

Cross Reference | NSN 5985-00-973-2806
Part Number Cage Code Manufacturer
SM-B-42402849675RCA CORP GOVERNMENT AND COMMERCIALSYSTEMS COMMERCIAL COMMICATIONS
SM-B-42402880063US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS
SM-B-42402820723VALCORE MANUFACTURING LLCDBA USE CAGE CODE 04YE2 FOR
Technical Data | NSN 5985-00-973-2806
Characteristic Specifications
STYLE DESIGNATOR COAXIAL MOUNTED
OVERALL LENGTH1.180 INCHES NOMINAL
OVERALL DIAMETER0.500 INCHES NOMINAL
POWER RATING0.125 WATTS AVERAGE
IMPEDANCE RATING IN OHMS47.0 NOMINAL
TERMINATION TYPE CONNECTION COAXIAL
COAXIAL CONNECTOR SERIES DESIGNATION BNC
CONNECTOR END DESIGN FEMALE
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS