NSN 5985-00-883-2452

Part Details | VARIABLE ATTENUATOR

5985-00-883-2452 A device for reducing the strength of an alternating current signal either continuously or in steps, without causing appreciable signal distortion, by maintaining substantially constant output and/or input impedance match. Continuously variable resistive devices must consist of at least two sections or one section with at least two rotating contacts. The item must have an overall attenuation rating. Includes tandem mounted variable resistors designed to function as an attenuator but whose terminals are not connected. See also RESISTOR, VAIABLE (as modified).

Alternate Parts: 100337, 5985-00-883-2452, 00-883-2452, 5985008832452, 008832452

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 05, 197200-883-245200838 ( ATTENUATOR, VARIABLE )
REFERENCE DRAWINGS & PICTURES

COAXIAL TYPE

Cross Reference | NSN 5985-00-883-2452
Part Number Cage Code Manufacturer
10033733013LOGIMETRICS INC
Technical Data | NSN 5985-00-883-2452
Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
FREQUENCY RANGE0.000 MEGAHERTZ MINIMUM AND 100.000 MEGAHERTZ MAXIMUM
IMPEDANCE RATING IN OHMS50.0 INPUT-OUTPUT
VOLTAGE STANDING WAVE RATIO1.04
POWER RATING500.0 MILLIWATTS PEAK
INSERTION LOSS AT MINIMUM ATTENUATION IN MAXIMUM DECIBELS0.2
OVERALL ATTENUATION RANGE IN DECIBELSP0.0/P120.0
OVERALL ATTENUATION ACCURACY IN DECIBELSM0.50/P0.50
ATTENUATION VARIATION METHOD STEPPED
STEP POSITION QUANTITY10
ATTENUATION PER STEP IN DECIBELS12.0
BODY STYLE COAXIAL TYPE
OVERALL LENGTH4.220 INCHES NOMINAL
OVERALL HEIGHT2.440 INCHES NOMINAL
OVERALL WIDTH3.560 INCHES NOMINAL
ADJUSTMENT DEVICE TYPE AND QUANTITY1 SHAFT
SHAFT TYPE ROUND
SHAFT DIAMETER0.249 INCHES NOMINAL
SHAFT LENGTH0.845 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 CONNECTOR, COAXIAL, FEMALE
COAXIAL CONNECTOR SERIES DESIGNATION BNC
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
MOUNTING FACILITY PATTERN FOUR POSITION RECTANGULAR
UNTHREADED MOUNTING HOLE DIAMETER0.187 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.093 INCHES NOMINAL
OPERATING TEMP RANGE+0.0 TO +50.0 DEG CELSIUS