NSN 5985-00-867-0717
Part Details | ELECTRICAL DUMMY LOAD
5985-00-867-0717 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.
Alternate Parts: 8340812, 834081-2, 5985-00-867-0717, 00-867-0717, 5985008670717, 008670717
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1960 | 00-867-0717 | 00335 ( DUMMY LOAD, ELECTRICAL ) |
REFERENCE DRAWINGS & PICTURES
WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-00-867-0717
Part Number | Cage Code | Manufacturer |
---|---|---|
834081-2 | 82577 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5985-00-867-0717
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | WAVEGUIDE MOUNTED |
POWER RATING | 30.000 WATTS AVERAGE |
VOLTAGE STANDING WAVE RATIO | 1.20 |
TERMINATION TYPE | WAVEGUIDE FLANGE |
INTERNAL OPERATING PRESSURE | 15.0 POUNDS PER SQUARE INCH GAGE |
COOLING METHOD | SELF-COOLED |
OPERATING POSITION | ALL POSITIONS |
SPECIAL FEATURES | PAINT ALL OUTER SURFACES DULL BLACK; DO NOT PAINT FLANGE FACES |
RF CONNECTOR CHANGING FEATURE | NOT INCLUDED |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |