NSN 5985-00-104-8513
Part Details | FIXED ATTENUATOR
5985-00-104-8513 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.
Alternate Parts: MDC1102B10, MDC1102B-10, 5L 5177.001.07, 766A10, 766A-10, 76610, 766-10, 88033000101, 8803300010-1, 5390713, 539071-3, 5985-00-104-8513, 00-104-8513, 5985001048513, 001048513
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUL 01, 1968 | 00-104-8513 | 14224 ( ATTENUATOR, FIXED ) |
REFERENCE DRAWINGS & PICTURES
ROUND, TERMINAL/TERMINALS IN OPPOSITE SURFACE

Cross Reference | NSN 5985-00-104-8513
Part Number | Cage Code | Manufacturer |
---|---|---|
MDC1102B-10 | 52335 | DAL-TECH DEVICES, INC.DBA MICROWAVE DISTRIBUTORS COMPANY |
5L 5177.001.07 | D1901 | HENSOLDT SENSORS GMBHDIV SEPS |
766A-10 | 99899 | L3 TECHNOLOGIES, INC.DBA NARDA MICROWAVE EAST |
766-10 | 99899 | L3 TECHNOLOGIES, INC.DBA NARDA MICROWAVE EAST |
8803300010-1 | 57057 | NAVCOM DEFENSE ELECTRONICS, INC. |
539071-3 | 96214 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5985-00-104-8513
Characteristic | Specifications |
---|---|
APPLICATION DESIGN | TRANSMISSION LINE |
INPUT IMPEDANCE RATING IN OHMS | 50.0 |
OUTPUT IMPEDANCE RATING IN OHMS | 50.0 |
FREQUENCY RANGE | 0.000 HERTZ MINIMUM AND 4.000 GIGAHERTZ MAXIMUM |
VOLTAGE STANDING WAVE RATIO | B1.10$$B1.15 |
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +0.0 TO +1.0 GIGAHERTZ AND +1.0 TO +4.0 GIGAHERTZ |
RF SIGNAL ATTENUATION IN DECIBELS | 10.0 |
ATTENUATION ACCURACY IN DECIBELS | M0.50/P0.50 |
POWER RATING | 20.0 WATTS AVERAGE |
OPERATING TEMP RANGE | -54.0 TO +55.0 DEG CELSIUS |
BODY STYLE | ROUND, TERMINAL/TERMINALS IN OPPOSITE SURFACE |
OVERALL LENGTH | 3.120 INCHES NOMINAL |
OVERALL DIAMETER | 1.500 INCHES NOMINAL |
BODY MATERIAL | METAL |
BODY SURFACE TREATMENT | ANY ACCEPTABLE |
TERMINAL TYPE AND QUANTITY | 2 CONNECTOR |
COAXIAL CONNECTOR SERIES DESIGNATION | N |
CONNECTION TYPE PER FUNCTION | FEMALE INPUT AND MALE OUTPUT |
MOUNTING METHOD | TERMINAL |