NSN 5962-01-170-0590

Part Details | LINEAR MICROCIRCUIT

5962-01-170-0590 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.

Alternate Parts: LO3337, KLJ1918A, KLJ1918A, UA7915KM, LM120K15, LM120K-15, 5962-01-170-0590, 01-170-0590, 5962011700590, 011700590

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 18, 198401-170-059031778 ( MICROCIRCUIT, LINEAR )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5962-01-170-0590
Part Number Cage Code Manufacturer
LO333716236DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
KLJ1918A06RP6DRS CONSOLIDATED CONTROLS, INC.
KLJ1918A02750EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION
UA7915KM07263FAIRCHILD SEMICONDUCTOR CORP
LM120K-1527014NATIONAL SEMICONDUCTOR CORPORATION
Technical Data | NSN 5962-01-170-0590
Characteristic Specifications
DESIGN FUNCTION AND QUANTITY1 REGULATOR, VOLTAGE
INPUT CIRCUIT PATTERN 1 INPUT
VOLTAGE RATING AND TYPE PER CHARACTERISTICACV35.0 VOLTS MAXIMUM
OPERATING TEMP RANGE-55.0 TO +125.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY3 PIN
TERMINAL SURFACE TREATMENT SOLDER
INCLOSURE CONFIGURATION CAN
INCLOSURE MATERIAL METAL
CASE OUTLINE SOURCE AND DESIGNATORT0-3 JOINT ELECTRON DEVICE ENGINEERING COUNCIL
BODY LENGTH1.439 INCHES MINIMUM AND 1.573 INCHES MAXIMUM
BODY HEIGHT0.250 INCHES MINIMUM AND 0.450 INCHES MAXIMUM
BODY WIDTH0.990 INCHES MINIMUM AND 1.050 INCHES MAXIMUM
STORAGE TEMP RANGE-65.0 TO +150.0 DEG CELSIUS
FEATURES PROVIDED HERMETICALLY SEALED AND MONOLITHIC AND NEGATIVE OUTPUTS AND POSITIVE OUTPUTS
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO.LO3337
TEST DATA DOCUMENT14933-L03337 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.).
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
CRITICALITY CODE JUSTIFICATIONFEAT