NSN 5955-00-133-0483
Part Details | QUARTZ CRYSTAL UNIT
5955-00-133-0483 An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.
Alternate Parts: CR19AU1200000MC, CR19AU12-00000MC, 2897012010, 289-7012-010, 2897012010, 289-7012-010, 5955-00-133-0483, 00-133-0483, 5955001330483, 001330483
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | DEC 18, 1968 | 00-133-0483 | 00196 ( CRYSTAL UNIT, QUARTZ ) |
REFERENCE DRAWINGS & PICTURES
OVAL BODY, PIN TERMINALS

Cross Reference | NSN 5955-00-133-0483
Part Number | Cage Code | Manufacturer |
---|---|---|
CR19AU12-00000MC | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
289-7012-010 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
289-7012-010 | 01281 | TRW ELECTRONICS AND DEFENSE SECTORRF DEVICES |
Technical Data | NSN 5955-00-133-0483
Characteristic | Specifications |
---|---|
MODE OF OSCILLATION | FUNDAMENTAL |
CIRCUIT RESONANCE | ANTIRESONANCE |
LOAD CAPACITANCE IN PICOFARADS | 29.5 MINIMUM AND 30.5 MAXIMUM |
SHUNT CAPACITANCE IN PICOFARADS | 7.0 MAXIMUM |
SPECIFIED FREQUENCY | 12.000 MEGAHERTZ |
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT | M0.005/P0.005 |
OPERATING TEMP RANGE | -55.0 TO +105.0 DEG CELSIUS |
EQUIVALENT RESISTANCE VALUE IN OHMS | 25.0 MAXIMUM |
DRIVE LEVEL RATING | 4.0 MILLIWATTS MINIMUM AND 6.0 MILLIWATTS MAXIMUM |
STYLE DESIGNATOR | OVAL BODY, PIN TERMINALS |
OVERALL LENGTH | 0.778 INCHES MAXIMUM |
TERMINAL LENGTH | 0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM |
OVERALL WIDTH | 0.435 INCHES MAXIMUM |
BODY LENGTH | 0.530 INCHES MAXIMUM |
BODY WIDTH | 0.402 INCHES MAXIMUM |
BODY THICKNESS | 0.150 INCHES MAXIMUM |
OVERALL THICKNESS | 0.183 INCHES MAXIMUM |
TERMINAL DIAMETER | 0.038 INCHES MINIMUM AND 0.042 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.184 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
HOLDER COVER MATERIAL | METAL |
TEST DATA DOCUMENT | 81349-MIL-C-3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |