NSN 5945-00-201-8592

Part Details | THERMAL RELAY

5945-00-201-8592 A relay switch which is actuated by the effect of internal heat generated by the current in its energizing circuit. For items actuated by ambient, rather than internal temperature changes, see SWITCH, THERMOSTATIC.

Alternate Parts: 11K156331PC4, 11K1563-31PC4, CR282434E109, CR2824-34E109, 11K21432PC5, 11K2143-2PC5, 5945-00-201-8592, 00-201-8592, 5945002018592, 002018592

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-201-859203883 ( RELAY, THERMAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-00-201-8592
Part Number Cage Code Manufacturer
11K1563-31PC424446GENERAL ELECTRIC COMPANY
CR2824-34E10924446GENERAL ELECTRIC COMPANY
11K2143-2PC524446GENERAL ELECTRIC COMPANY
Technical Data | NSN 5945-00-201-8592
Characteristic Specifications
CONTACT ARRANGEMENT SINGLE POLE, SINGLE THROW, NORMALLY CLOSED
CONTACT MAXIMUM VOLTAGE RATING IN VOLTS550.0 AC
CONTACT MAXIMUM CURRENT RATING IN AMPS20.0 AC
MOUNTING FACILITY TYPE AND QUANTITY3 UNTHREADED HOLE
OVERALL LENGTH5.438 INCHES NOMINAL
OVERALL WIDTH4.500 INCHES NOMINAL
OVERALL HEIGHT4.219 INCHES NOMINAL
ENVIRONMENTAL PROTECTION FIRE RESISTANT
SPECIAL FEATURESHEATER DATA,AC,V NOT RATED,WATTAGE NOT RATED,1.65 AMP;TERMINAL DATA,2 HEATER ELEMENT TERMINALS,2 TERMINALS FOR CONTACT;PLASTIC CASE;NOT RATED FOR AMBIENT TEMP RANGE COMPENSATION;RATED FOR ACTUATION TIME,900 SEC AT 125 PCT OF CONTINUOUS LOAD,175 SEC AT 200 PCT OF CONTINUOUS LOAD,72 SEC AT 300 PCT OFCONTINUOUS LOAD OPERATING TIME;SPECIAL FEATURES,LONG RESET ROD,ADUSTABLE 90 TO 110 PCT OF RATING,COIL W/10 IN. LEADS,NO TERMINALS,FOR GENERAL PURPOSE USE