NSN 5930-00-358-1005

Part Details | THERMOSTATIC SWITCH

5930-00-358-1005 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 837AC11FMC, 837A3A, 837-A3A, 5930-00-358-1005, 00-358-1005, 5930003581005, 003581005

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59FEB 18, 197400-358-100500451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR

Cross Reference | NSN 5930-00-358-1005
Part Number Cage Code Manufacturer
837AC11FMC01121ROCKWELL AUTOMATION, INC.
837-A3A01121ROCKWELL AUTOMATION, INC.
Technical Data | NSN 5930-00-358-1005
Characteristic Specifications
STYLE DESIGNATOR3 RECTANGULAR
OVERALL LENGTH2.562 INCHES NOMINAL
OVERALL HEIGHT5.250 INCHES NOMINAL
OVERALL WIDTH3.250 INCHES NOMINAL
BODY HEIGHT4.625 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+25.00 TO +125.00 ACTUATION POINT DEGREES FAHRENHEIT AND +25.00 TO +125.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW
CONTACT STIMULUS RATINGAF2.00 DIFFERENTIAL POINT MINIMUM AND AF18.00 DIFFERENTIAL POINT MAXIMUM
OPERATING TEMP RATING160.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH72.0 INCHES NOMINAL
BULB LENGTH8.500 INCHES NOMINAL
BULB DIAMETER0.375 INCHES NOMINAL
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD BASE AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.219 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION DIAGONAL
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.000 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS2.000 INCHES NOMINAL
FEATURES PROVIDED ELECTRICAL ACCESS PORT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION GENERAL PURPOSE-NEMA TYPE 1