NSN 5930-00-358-1005
Part Details | THERMOSTATIC SWITCH
5930-00-358-1005 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 837AC11FMC, 837A3A, 837-A3A, 5930-00-358-1005, 00-358-1005, 5930003581005, 003581005
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | FEB 18, 1974 | 00-358-1005 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR

Cross Reference | NSN 5930-00-358-1005
Part Number | Cage Code | Manufacturer |
---|---|---|
837AC11FMC | 01121 | ROCKWELL AUTOMATION, INC. |
837-A3A | 01121 | ROCKWELL AUTOMATION, INC. |
Technical Data | NSN 5930-00-358-1005
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 3 RECTANGULAR |
OVERALL LENGTH | 2.562 INCHES NOMINAL |
OVERALL HEIGHT | 5.250 INCHES NOMINAL |
OVERALL WIDTH | 3.250 INCHES NOMINAL |
BODY HEIGHT | 4.625 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +25.00 TO +125.00 ACTUATION POINT DEGREES FAHRENHEIT AND +25.00 TO +125.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW |
CONTACT STIMULUS RATING | AF2.00 DIFFERENTIAL POINT MINIMUM AND AF18.00 DIFFERENTIAL POINT MAXIMUM |
OPERATING TEMP RATING | 160.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
CAPILLARY TUBE LENGTH | 72.0 INCHES NOMINAL |
BULB LENGTH | 8.500 INCHES NOMINAL |
BULB DIAMETER | 0.375 INCHES NOMINAL |
TERMINAL TYPE | TAB W/SCREW |
MOUNTING METHOD | BASE AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.000 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.000 INCHES NOMINAL |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |