NSN 5925-00-233-5125
Part Details | CIRCUIT BREAKER
5925-00-233-5125 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: 71152535, 711525-35, 675230215, 6752-302-15, 5925-00-233-5125, 00-233-5125, 5925002335125, 002335125
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | NOV 02, 1970 | 00-233-5125 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
MULTIPOLE-SINGLE ACTUATOR TYPE
Cross Reference | NSN 5925-00-233-5125
Part Number | Cage Code | Manufacturer |
---|---|---|
711525-35 | 05869 | RAYTHEON COMPANYDBA RAYTHEON |
6752-302-15 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
Technical Data | NSN 5925-00-233-5125
Characteristic | Specifications |
---|---|
POLE QUANTITY | 3 |
TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |
RESET METHOD | MANUAL |
BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
CASE MATERIAL | PLASTIC |
MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
BUSHING LENGTH | 0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM |
BODY LENGTH | 2.250 INCHES MAXIMUM |
BODY WIDTH | 2.189 INCHES MAXIMUM |
BODY HEIGHT | 2.460 INCHES MINIMUM AND 2.480 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.800 INCHES MINIMUM AND 1.820 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.138 INCHES |
THREAD QUANTITY PER INCH | 32 |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
ACTUATOR FUNCTION | TRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT POLE TWO |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE THREE |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
SWITCH CURRENT RATING AND TYPE IN AMPS | 7.0 DC |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 28.0 DC |
SWITCH TERMINAL TYPE | TURRET |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
STORAGE TYPE | E ANY ACCEPTABLE |
UNPACKAGED UNIT WEIGHT | 2.100 POUNDS |
SPECIAL HANDLING FEATURE | MAGNETIC |
FRAGILITY FACTOR | MODERATELY RUGGED |