NSN 5925-00-174-3340

Part Details | CIRCUIT BREAKER

5925-00-174-3340 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: P2263SM6050, P2263SM6-0-50, P2263SMG405250VAC60, P2263SMG4-0-5-250VAC60, 5925-00-174-3340, 00-174-3340, 5925001743340, 001743340

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-174-334000136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-SINGLE ACTUATOR TYPE

Cross Reference | NSN 5925-00-174-3340
Part Number Cage Code Manufacturer
P2263SM6-0-5074193EATON CORPHEINEMANN PRODUCTS
P2263SMG4-0-5-250VAC6074193EATON CORPHEINEMANN PRODUCTS
Technical Data | NSN 5925-00-174-3340
Characteristic Specifications
POLE QUANTITY2
TERMINAL TYPE AND QUANTITY4 THREADED STUD
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY WIDTH1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
BOSS HEIGHT0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE3.303 INCHES MINIMUM AND 3.323 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED