NSN 5925-00-173-7650
Part Details | CIRCUIT BREAKER
5925-00-173-7650 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: MCA2, CA2, CA2, 5925-00-173-7650, 00-173-7650, 5925001737650, 001737650
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-173-7650 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
SINGLE POLE TYPE
Cross Reference | NSN 5925-00-173-7650
Part Number | Cage Code | Manufacturer |
---|---|---|
MCA2 | 91340 | MET-PRO CORPORATION |
CA2 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
CA2 | 14859 | TEXAS INSTRUMENTS INCCONTROL PRODUCTS DIV |
Technical Data | NSN 5925-00-173-7650
Characteristic | Specifications |
---|---|
POLE QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
RESET METHOD | AUTOMATIC |
BODY STYLE | SINGLE POLE TYPE |
CASE MATERIAL | PLASTIC |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
OVERALL LENGTH | 2.000 INCHES NOMINAL |
BODY WIDTH | 1.343 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.574 INCHES NOMINAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.234 INCHES NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
STORAGE TYPE | E ANY ACCEPTABLE |
UNPACKAGED UNIT WEIGHT | 1.000 OUNCES |
FRAGILITY FACTOR | MODERATELY RUGGED |