NSN 5925-00-147-0749

Part Details | CIRCUIT BREAKER

5925-00-147-0749 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: APL11RR5964, APL11RR596-4, 0005644004, 0005-644-004, 5644004, 5-644-004, 5925-00-147-0749, 00-147-0749, 5925001470749, 001470749

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59SEP 15, 197100-147-074900136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-MULTIPLE ACTUATOR TYPE

Cross Reference | NSN 5925-00-147-0749
Part Number Cage Code Manufacturer
APL11RR596-481541SENSATA TECHNOLOGIES MARYLAND, INC
0005-644-00493929SPX CORPORATIONDBA RADIODETECTION
5-644-00493929SPX CORPORATIONDBA RADIODETECTION
Technical Data | NSN 5925-00-147-0749
Characteristic Specifications
POLE QUANTITY2
TERMINAL TYPE AND QUANTITY4 THREADED STUD
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY WIDTH1.515 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
BOSS HEIGHT0.150 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE2.625 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
THREAD PITCH DIAMETERS+0.1177 TO +0.1214 INCHES
MANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT EACH POLE
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS10.0 AC AND 10.0 DC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC AND 65.0 DC
SWITCH TERMINAL TYPE PIN
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF AND FUNGUS RESISTANT
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
UNPACKAGED UNIT WEIGHT7.400 OUNCES
SPECIAL HANDLING FEATURE MAGNETIC
FRAGILITY FACTOR MODERATELY RUGGED