NSN 5925-00-116-4360
Part Details | CIRCUIT BREAKER
5925-00-116-4360 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: R1144, 5925-00-116-4360, 00-116-4360, 5925001164360, 001164360
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | SEP 27, 1968 | 00-116-4360 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
SINGLE POLE TYPE
Cross Reference | NSN 5925-00-116-4360
Part Number | Cage Code | Manufacturer |
---|---|---|
R1144 | 17032 | VALAD ELECTRIC HEATING CORP. |
Technical Data | NSN 5925-00-116-4360
Characteristic | Specifications |
---|---|
POLE QUANTITY | 1 |
BODY STYLE | SINGLE POLE TYPE |
BUSHING LENGTH | 0.562 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.656 INCHES NOMINAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.562 INCHES NOMINAL |