NSN 5925-00-102-7825

Part Details | CIRCUIT BREAKER

5925-00-102-7825 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: STSVC004253, STSVC004-253, 675230925, 6752-309-25, 5925-00-102-7825, 00-102-7825, 5925001027825, 001027825

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 31, 196800-102-782500136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-SINGLE ACTUATOR TYPE

Cross Reference | NSN 5925-00-102-7825
Part Number Cage Code Manufacturer
STSVC004-25398897LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN AERONAUTICS
6752-309-2582647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
Technical Data | NSN 5925-00-102-7825
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 TAB W/SCREW
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BUSHING LENGTH0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM
BODY LENGTH2.250 INCHES MAXIMUM
BODY WIDTH2.189 INCHES MAXIMUM
BODY HEIGHT2.340 INCHES MINIMUM AND 2.400 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.161 INCHES MINIMUM AND 1.220 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.470 INCHES MINIMUM AND 1.530 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
TEST DATA DOCUMENT98897-STSV004 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
STORAGE TYPEE ANY ACCEPTABLE
UNPACKAGED UNIT WEIGHT3.250 OUNCES
FRAGILITY FACTOR MODERATELY RUGGED