NSN 5925-00-079-7401

Part Details | CIRCUIT BREAKER

5925-00-079-7401 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 7400523, 740052-3, 152600715, 1526-007-15, 5925-00-079-7401, 00-079-7401, 5925000797401, 000797401

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-079-740100136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5925-00-079-7401
Part Number Cage Code Manufacturer
740052-398897LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN AERONAUTICS
1526-007-1581640SAFRAN ELECTRICAL & POWER USA, LLCDBA LABINAL POWER SYSYEMS
Technical Data | NSN 5925-00-079-7401
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 THREADED STUD
RESET METHOD MANUAL
CASE MATERIAL PLASTIC
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
OVERALL LENGTH3.535 INCHES NOMINAL
OVERALL HEIGHT1.250 INCHES NOMINAL
OVERALL WIDTH2.063 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
ACTUATOR FUNCTION TRIP-RESET
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED EXPLOSION PROOF
ARC QUENCHING METHOD AIR