NSN 5925-00-069-1306

Part Details | CIRCUIT BREAKER

5925-00-069-1306 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 13214E37113, 13214E3711-3, 701972MG6, 70-197-2MG6, 5925-00-069-1306, 00-069-1306, 5925000691306, 000691306

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 07, 196700-069-130600136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

Cross Reference | NSN 5925-00-069-1306
Part Number Cage Code Manufacturer
13214E3711-397403CECOM LR CENTER
70-197-2MG674193EATON CORPHEINEMANN PRODUCTS
Technical Data | NSN 5925-00-069-1306
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 THREADED STUD
RESET METHOD MANUAL
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH2.540 INCHES MAXIMUM
BODY WIDTH0.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.970 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.060 INCHES NOMINAL
BOSS HEIGHT0.140 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE2.770 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS2.5 AC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC
SWITCH TERMINAL TYPE TAB, SOLDER LUG
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED MOISTURE RESISTANT AND FUNGUS RESISTANT
STORAGE TYPEE ANY ACCEPTABLE