NSN 5925-00-045-5295

Part Details | CIRCUIT BREAKER

5925-00-045-5295 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: AM15167250VAC60C1, AM1516-7-250VAC60C1, AM1516, 5925-00-045-5295, 00-045-5295, 5925000455295, 000455295

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196100-045-529500136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

Cross Reference | NSN 5925-00-045-5295
Part Number Cage Code Manufacturer
AM1516-7-250VAC60C174193EATON CORPHEINEMANN PRODUCTS
AM151674193EATON CORPHEINEMANN PRODUCTS
Technical Data | NSN 5925-00-045-5295
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 THREADED STUD
RESET METHOD MANUAL
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH3.719 INCHES NOMINAL
BODY WIDTH0.990 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.063 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.750 INCHES NOMINAL
BOSS HEIGHT0.156 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE3.239 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED EXPLOSION RESISTANT
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSAS DIFFERENTIATED BY CONTINUOUS LOAD AND TIME DELAY
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
SPECIAL HANDLING FEATURE MAGNETIC
FRAGILITY FACTOR MODERATELY RUGGED