NSN 5925-00-027-2764

Part Details | CIRCUIT BREAKER

5925-00-027-2764 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 2711290P2, 271-1290P2, 2711290P2, 271-1290P2, 5925-00-027-2764, 00-027-2764, 5925000272764, 000272764

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-027-276400136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

Cross Reference | NSN 5925-00-027-2764
Part Number Cage Code Manufacturer
271-1290P249956RAYTHEON COMPANYDBA RAYTHEON
271-1290P23B150RAYTHEON COMPANYDBA RAYTHEON
Technical Data | NSN 5925-00-027-2764
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 THREADED STUD
RESET METHOD MANUAL
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH2.500 INCHES NOMINAL
BODY WIDTH0.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.938 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.062 INCHES NOMINAL
BOSS HEIGHT0.140 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE2.471 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.190 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE