NSN 5925-00-008-0550
Part Details | CIRCUIT BREAKER
5925-00-008-0550 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: L104329, D37203, 3010315, 30103-15, 5925-00-008-0550, 00-008-0550, 5925000080550, 000080550
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUL 09, 1972 | 00-008-0550 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
SINGLE POLE TYPE
Cross Reference | NSN 5925-00-008-0550
Part Number | Cage Code | Manufacturer |
---|---|---|
L104329 | 10988 | CNH INDUSTRIAL AMERICA LLC |
D37203 | 10988 | CNH INDUSTRIAL AMERICA LLC |
30103-15 | 13445 | COLE HERSEE COMPANY |
Technical Data | NSN 5925-00-008-0550
Characteristic | Specifications |
---|---|
POLE QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
RESET METHOD | AUTOMATIC |
BODY STYLE | SINGLE POLE TYPE |
CASE MATERIAL | METAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
OVERALL LENGTH | 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM |
BODY WIDTH | 0.775 INCHES MINIMUM AND 0.786 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.673 INCHES MINIMUM AND 0.683 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.557 INCHES MINIMUM AND 1.567 INCHES MAXIMUM |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.365 INCHES MINIMUM AND 1.375 INCHES MAXIMUM |
UNTHREADED MOUNTING HOLE DIAMETER | 0.215 INCHES MINIMUM AND 0.225 INCHES MAXIMUM |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
STORAGE TYPE | E ANY ACCEPTABLE |
FRAGILITY FACTOR | MODERATELY RUGGED |