NSN 5910-00-435-6409
Part Details | ELECTROLYTIC FIXED CAPACITOR
5910-00-435-6409 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: 790269606, 7902696-06, MILC390031, MILC39003-1, CSR13B277KM, M39003012250, M39003-01-2250, M3900012250, M3900-01-2250, 5910-00-435-6409, 00-435-6409, 5910004356409, 004356409
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAR 26, 1969 | 00-435-6409 | 00008 ( CAPACITOR, FIXED, ELECTROLYTIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, AXIAL TERMINALS

ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL

Cross Reference | NSN 5910-00-435-6409
Part Number | Cage Code | Manufacturer |
---|---|---|
7902696-06 | 90536 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
MILC39003-1 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
CSR13B277KM | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
M39003-01-2250 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
M3900-01-2250 | 82214 | UNION CARBIDE CORPELECTRONIC SPECIALTY PRODUCTS GROUP |
Technical Data | NSN 5910-00-435-6409
Characteristic | Specifications |
---|---|
CAPACITANCE VALUE PER SECTION | 270.000 MICROFARADS SINGLE SECTION |
TOLERANCE RANGE PER SECTION | -10.00 TO +10.00 PERCENT SINGLE SECTION |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 6.0 DC SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
BODY DIAMETER | 0.351 INCHES NOMINAL |
BODY LENGTH | 0.786 INCHES NOMINAL |
SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TERMINAL LENGTH | 1.500 INCHES NOMINAL |
TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
CASE MATERIAL | METAL |
CASE INSULATION MATERIAL | PLASTIC |
CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 8.0000 |
DC LEAKAGE AT REFERENCE TEMP | 13.000 MICROAMPERES |
ELECTRICAL POLARIZATION | POLARIZED |
RELIABILITY INDICATOR | ESTABLISHED |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.0000 |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
TEST DATA DOCUMENT | 81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL-C-39003 TO 1 GOVERNMENT SPECIFICATION |
MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-3 |
ANODE TYPE | SOLID |
DC LEAKAGE AT MAXIMUM OPERATING TEMP | 130.0 MICROAMPERES |