NSN 5905-00-141-1347
Part Details | WIRE WOUND FIXED RESISTOR
5905-00-141-1347 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self supporting. Opposition to the flow of current is an inherent property of the resistance wire and is manifest by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE.
Alternate Parts: RB73CE10001B, MILR9328, MILR93-28, 5905-00-141-1347, 00-141-1347, 5905001411347, 001411347
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | DEC 30, 1968 | 00-141-1347 | 00010 ( RESISTOR, FIXED, WIRE WOUND ) |
REFERENCE DRAWINGS & PICTURES
RADIAL TERMINAL EACH END

Cross Reference | NSN 5905-00-141-1347
Part Number | Cage Code | Manufacturer |
---|---|---|
RB73CE10001B | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MILR93-28 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5905-00-141-1347
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 10.000 KILOHMS |
RESISTANCE TOLERANCE IN PERCENT | M0.100/P0.100 |
POWER DISSIPATION RATING IN WATTS | 1.500 FREE AIR |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | M20.0/P20.0 |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | M65.0/P145.0 |
INCLOSURE METHOD | ENCAPSULATED |
STYLE DESIGNATOR | RADIAL TERMINAL EACH END |
BODY DIAMETER | 0.500 INCHES NOMINAL |
BODY LENGTH | 2.000 INCHES NOMINAL |
TERMINAL TYPE | TAB, SOLDER LUG |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TERMINAL LENGTH | 0.375 INCHES NOMINAL |
TERMINAL WIDTH | 0.188 INCHES NOMINAL |