NSN 5905-00-138-1280

Part Details | WIRE WOUND FIXED RESISTOR

5905-00-138-1280 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self supporting. Opposition to the flow of current is an inherent property of the resistance wire and is manifest by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE.

Alternate Parts: 26351150119, 2635-115-01-19, 338345304, 338345-304, RER65F1210, MILR390091, MIL-R-39009/1, RER65F1210R, RER65F1210P, 808706865219, 808-7068652-19, 90R123121F, 90R123-121F, 90R123121E, 90R123-121E, 90R123121F, 90R123-121F, 05900337, 059-00337, 538079297, 538079-297, RH101210HMP0RM3, RH10-1210HMP0RM3, 5905-00-138-1280, 00-138-1280, 5905001381280, 001381280

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 09, 197100-138-128000010 ( RESISTOR, FIXED, WIRE WOUND )
REFERENCE DRAWINGS & PICTURES

AXIAL TERMINAL EACH END

Cross Reference | NSN 5905-00-138-1280
Part Number Cage Code Manufacturer
2635-115-01-1996169ELECTRIC BOAT CORPORATION
338345-30456232LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
RER65F121081349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-R-39009/181349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
RER65F1210R81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
RER65F1210P81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
808-7068652-1953711NAVAL SEA SYSTEMS COMMAND
90R123-121F76823NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN AEROSPACE
90R123-121E76823NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN AEROSPACE
90R123-121F0JRC1NORTHROP GRUMMAN TECHNICAL SERVICES,INC.
059-0033704801POWER PARAGON INCDBA POWER SYSTEMS GROUP
538079-29796214RAYTHEON COMPANYDBA RAYTHEON
RH10-1210HMP0RM391637VISHAY DALE ELECTRONICS, LLCDBA VISHAY INTERTECHNOLOGY
Technical Data | NSN 5905-00-138-1280
Characteristic Specifications
ELECTRICAL RESISTANCE121.000 OHMS
RESISTANCE TOLERANCE IN PERCENTM1.000/P1.000
POWER DISSIPATION RATING IN WATTS6.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER25.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER275.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUSM30.0/P30.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUSM55.0/P275.0
INCLOSURE METHOD ENCASED
STYLE DESIGNATOR48 AXIAL TERMINAL EACH END
BODY LENGTH0.688 INCHES MINIMUM AND 0.812 INCHES MAXIMUM
BODY WIDTH0.376 INCHES MINIMUM AND 0.428 INCHES MAXIMUM
BODY HEIGHT0.375 INCHES MINIMUM AND 0.437 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.552 INCHES MINIMUM AND 0.572 INCHES MAXIMUM
MOUNTING HOLE SIZE0.089 INCHES MINIMUM AND 0.099 INCHES MAXIMUM
TERMINAL TYPE TAB, SOLDER LUG
RELIABILITY INDICATOR ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
TERMINAL LENGTH0.250 INCHES MINIMUM AND 0.374 INCHES MAXIMUM
TERMINAL WIDTH0.140 INCHES MINIMUM
CUBIC MEASURE0.133 CUBIC INCHES
TEST DATA DOCUMENT81349-MIL-R-39009 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-R-39009 TO 1 GOVERNMENT SPECIFICATION
UNPACKAGED UNIT WEIGHT8.0 GRAMS