NSN 5905-00-114-5343
Part Details | COMPOSITION FIXED RESISTOR
5905-00-114-5343 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of a mixture of carbon, an insulating material, and suitable binders, either molded together or applied as a thin layer of conducting material on an insulated form. The opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the item itself. See also ATTENUATOR, FIXED; RESISTOR, FIXED, FILM; and RESISTOR, THERMAL. Excludes SUPPRESSOR, IGNITION INTERFERENCE.
Alternate Parts: 21007182, 21-007182, 25354182, 2535-4182, A8555, CR141801J, CR1-4-1801J, 91102020079, 911-0202-0079, G302116J182, 4700018212, 4700-0182-12, 7599096, 202182, 20-2182, 1020182, 102-0182, 224680789, 224680-789, 4431466055, 443-1466-055, 510058, 900034182, 900034-182, 200073180, 200073-180, 57312001500, 57312-0015-00, 10047690182, 10047-690-182, 1001825, 100-1825, 8550110183, 855011-0183, 549511801, 54951-1801, 5510101JK001R8, 55-10101JK001R8, 401018200, 4010182-00, 400512069, 400-512-069, 400512069, 400-512-069, 441444, 573220, F52003506, 35D07761825, 35D0776182-5, 045720, 045-720, 411829251001, 41182925-1001, 5241111182, 5-241111-182, OC1825, 5M.5102.229.76, 06841821, 0684-1821, 250093255, 2500932-55, 135018212, 135-0182-12, RG14182J, RG1-4-182J, 311009182, 311-009-182, JANRCR07G182JR, JANRCR07G182JM, 198200182, 198200-182, 91102020079, 911-0202-0079, 06001804041, 060-01804-041, 9999514, 339099055, 339099-055, 790275168, 7902751-68, 700176, RC07GF182K, RCR07G182KS, RCR07G182JS, RCR07G182JR, RCR07G182JP, RCR07G182JM, RCR07GF182K, RCR07GF182JM, RCR05G182JS, MILR390081, MIL-R-39008/1, JANRCR07G182JS, M1318254, M13-18254, 6S10401C55, 6129269, 6-129269, 3R152P182J, 3R152-P182J, 882761, 5C12721825, 5C127-21825, 5C12721821, 5C127-21821, 10120268, 1370071825, 137-007-1825, 450841182, 450-841182, 139A905362, 10003010355, 1-0003-0103-55, 41876793, 418767-93, 4171306366, 4171306-366, 41000275035, 410-00275-035, 1000275035, 10-00275-035, CB18K5PCT, CB1-8K5PCT, RC07GF182J, CB1825, CB182518K 14WA, CB182-5-1-8K 1-4WA, 7450757000, 745-0757-000, R25J182, 500 00182 00, 315018200, 315-0182-00, 0611009E55, 101602F, TRCC1821, 8497660182, 849766-0182, 41181 34180, RB218200, RB2182-00, 124647900, 1-246-479-00, 121255000, 1-212-550-00, 2036500709, 5905-00-114-5343, 00-114-5343, 5905001145343, 001145343
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | SEP 25, 1968 | 00-114-5343 | 00126 ( RESISTOR, FIXED, COMPOSITION ) |
REFERENCE DRAWINGS & PICTURES
AXIAL TERMINAL EACH END

Cross Reference | NSN 5905-00-114-5343
Part Number | Cage Code | Manufacturer |
---|---|---|
21-007182 | 11359 | ADAGE INC |
2535-4182 | 33967 | ADVANCED ANALOG INC.DBA INTERNATIONAL RECTIFIER |
A8555 | 81535 | AERONAUTICAL COMMUNICATIONSEQUIPMENT INC |
CR1-4-1801J | 09021 | AIRCO INCAIRCO ELECTRONICS |
911-0202-0079 | A0307 | ALENIA SISTEMI DIFESA SPA |
G302116J182 | 64959 | AMERICAN TELEPHONE AND TELEGRAPH CO |
4700-0182-12 | 14010 | ANADEX INC |
7599096 | 19204 | ARMY, UNITED STATES DEPARTMENT OFTHE |
20-2182 | 21793 | ASTRONICS TEST SYSTEMS INC. |
102-0182 | 54817 | AUTEK SYSTEMS CORP |
224680-789 | 81413 | BAE SYSTEMS INFORMATION ANDELECTRONIC SYSTEMS INTEGRATION I |
443-1466-055 | 94756 | BOEING COMPANY, THEDBA BOEING |
510058 | 16067 | CALIFORNIA INSTRUMENTS CORP |
900034-182 | 55788 | CATEL TELECOMMUNICATIONS INCSUB OF DATA-DESIGN LABORATORIES |
200073-180 | 32274 | CIPHER DATA PRODUCTS INCOEM MARKETING DIV |
57312-0015-00 | 30331 | CONCURRENT COMPUTER CORPORATION |
10047-690-182 | 18192 | COOPER CROUSE-HINDS, LLCDBA AIRPORT LIGHTING DIVISION |
100-1825 | 32097 | DDC PERTEC PERIPHERALS CORP |
855011-0183 | 55819 | DIAMOND ELECTRONICS INC |
54951-1801 | 12692 | DIGITAL DEVELOPMENT CORPHAWTHORNE DIV |
55-10101JK001R8 | 16152 | DIGITEC CORP |
4010182-00 | 34257 | EIP MICROWAVE INC |
400-512-069 | C3141 | ELETTRONICA GMBH |
400-512-069 | A1997 | ELETTRONICA SPA |
441444 | 89536 | FLUKE CORPORATION |
573220 | 89536 | FLUKE CORPORATION |
F52003506 | 65519 | FSG INC |
35D0776182-5 | 04655 | GENERAL DYNAMICS MISSION SYSTEMS,INC. |
045-720 | 01113 | GENERAL INSTRUMENT CORPORATIONDBA MOTOROLA |
41182925-1001 | 50163 | GENICOM CORP |
5-241111-182 | 96795 | GOULD INSTRUMENT SYSTEMS INC |
OC1825 | 44655 | HEICO OHMITE, L.L.C.DBA OHMITE MANUFACTURING |
5M.5102.229.76 | D1901 | HENSOLDT SENSORS GMBHDIV SEPS |
0684-1821 | 28480 | HEWLETT-PACKARD COMPANYDBA HP |
2500932-55 | 07187 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
135-0182-12 | 22373 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
RG1-4-182J | 11502 | INTERNATIONAL RESISTIVE COMPANY,INC. |
311-009-182 | 07421 | INTERSTATE ELECTRONICS CORPORATIONDBA L-3 INTERSTATE ELECTRONICS |
JANRCR07G182JR | 81350 | JOINT ARMY-NAVY SPECIFICATIONSPROMULGATED BY MILITARY DEPARTMENTS |
JANRCR07G182JM | 81350 | JOINT ARMY-NAVY SPECIFICATIONSPROMULGATED BY MILITARY DEPARTMENTS |
198200-182 | 06141 | L3 AVIATION PRODUCTS, INC. |
911-0202-0079 | A0810 | LEONARDO S.P.A. - AIRBORNE & SPACESYSTEM DIVISION |
060-01804-041 | 12131 | LH ENTERPRISE |
9999514 | 31498 | LJF CORP |
339099-055 | 56232 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
7902751-68 | 90536 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
700176 | 33013 | LOGIMETRICS INC |
RC07GF182K | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR07G182KS | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR07G182JS | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR07G182JR | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR07G182JP | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR07G182JM | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR07GF182K | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR07GF182JM | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR05G182JS | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-R-39008/1 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
JANRCR07G182JS | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
M13-18254 | 54418 | MILTOPE CORPORATION |
6S10401C55 | 94990 | MOTOROLA INC.DBA INTEGRATED INFORMATION SYSTEMS |
6-129269 | 94990 | MOTOROLA INC.DBA INTEGRATED INFORMATION SYSTEMS |
3R152-P182J | 33173 | MPD, INC. |
882761 | 07342 | NAI TECHNOLOGIES INC |
5C127-21825 | 06602 | NEXTIRAONE SOLUTIONS LLC |
5C127-21821 | 06602 | NEXTIRAONE SOLUTIONS LLC |
10120268 | A486G | NIMIKKEISTOKESKUS NCB FINLAND |
137-007-1825 | 95542 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
450-841182 | 26916 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MULTIPLE |
139A905362 | 03956 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NAVIGATION AND MARITIME SYSTEMS |
1-0003-0103-55 | 08642 | QUADRI CORP |
418767-93 | 96214 | RAYTHEON COMPANYDBA RAYTHEON |
4171306-366 | 05869 | RAYTHEON COMPANYDBA RAYTHEON |
410-00275-035 | 00724 | RAYTHEON COMPANYDBA RAYTHEON |
10-00275-035 | 00724 | RAYTHEON COMPANYDBA RAYTHEON |
CB1-8K5PCT | 01121 | ROCKWELL AUTOMATION, INC. |
RC07GF182J | 01121 | ROCKWELL AUTOMATION, INC. |
CB1825 | 01121 | ROCKWELL AUTOMATION, INC. |
CB182-5-1-8K 1-4WA | 01121 | ROCKWELL AUTOMATION, INC. |
745-0757-000 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
R25J182 | 65940 | ROHM CORP |
500 00182 00 | 18410 | RYCOM INSTRUMENTS, INC. |
315-0182-00 | 59873 | SPACELABS-HILLSBORO OPERATIONSSQUIBB VITATEK INC |
0611009E55 | 01537 | STATE HEALTH SERVICES, TEXASDEPARTMENT OF |
101602F | 52542 | SYSTRON-DONNER CORPMICROWAVE/INSTRUMENT DIV |
TRCC1821 | 10241 | TELEPHONE SYSTEMS/COMMUNICATIONS |
849766-0182 | 65597 | THALES DEFENSE & SECURITY, INC. |
41181 34180 | D8385 | THALES DEUTSCHLAND GMBHDBA VERTEIDIGUNGSSYSTEME SEL GMBH |
RB2182-00 | 32760 | THOMSON INCDIV GRASS VALLEY |
1-246-479-00 | 56614 | VIDEOTEK INC. |
1-212-550-00 | 56614 | VIDEOTEK INC. |
2036500709 | 56614 | VIDEOTEK INC. |
Technical Data | NSN 5905-00-114-5343
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 1.800 KILOHMS |
RESISTANCE TOLERANCE IN PERCENT | M5.000/P5.000 |
POWER DISSIPATION RATING IN WATTS | 0.250 FREE AIR |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 130.0 |
INCLOSURE METHOD | ENCAPSULATED |
STYLE DESIGNATOR | 4 AXIAL TERMINAL EACH END |
BODY DIAMETER | 0.090 INCHES NOMINAL |
BODY LENGTH | 0.250 INCHES NOMINAL |
TERMINAL TYPE | WIRE LEAD |
RELIABILITY INDICATOR | ESTABLISHED |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
TERMINAL LENGTH | 1.500 INCHES NOMINAL |
CUBIC MEASURE | 0.002 CUBIC INCHES |
TEST DATA DOCUMENT | 81349-MIL-R-39008 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39008 TO 1 GOVERNMENT SPECIFICATION |
UNPACKAGED UNIT WEIGHT | 0.300 GRAMS |