NSN 5805-01-556-1874
Part Details | TELEPHONE MONITORING SET
5805-01-556-1874 The components and items required to operate a complete electronic system for tapping into telephone lines at telephone central offices to listen to and/or record conversation being monitored. Includes monitoring cabinet(s), patching panel(s), and may or may not include recorder(s).
Alternate Parts: TALON TELEPHONE & LINE ANALYSER, TALAN, DPA7000, DPA-7000, 5805-01-556-1874, 01-556-1874, 5805015561874, 015561874
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | SEP 26, 2007 | 01-556-1874 | 04532 ( MONITORING SET, TELEPHONE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5805-01-556-1874
Part Number | Cage Code | Manufacturer |
---|---|---|
TALON TELEPHONE & LINE ANALYSER | U0KY7 | KAREEM SERVICES |
TALAN | 3Y543 | RESEARCH ELECTRONICS INTERNATIONAL,L.L.C. |
DPA-7000 | 3Y543 | RESEARCH ELECTRONICS INTERNATIONAL,L.L.C. |
Technical Data | NSN 5805-01-556-1874
Characteristic | Specifications |
---|---|
END ITEM NAME | TALAN TELEPHONE AND LINE ANALYZER |
SPECIAL FEATURES | TELEPHONE AND LINE ANALYZER; TESTS VOLTAGE, CURRENT, RESISTANCE, CAPACITANCE, NON-LINEAR JUNCTION DETECTION, FREQUENCY DOMAIN REFLECTIVITY AND DIGITAL DEMODULATION; CHECKS FOR WIRE TAPSON PHONES; TRACES WIRES AND ELECTRONIC DEVICES; MUTI-TEST DATA BASE WITH BREAKTHROUGH NEW TECHNOLOGY; PRIMARY CPU IS 32 BIT RISE PROCESSOR 520MHZ; INTERNAL MEMORY 64MB S-DRAM(OS), 64MB FLASH; USB A/B CONNECTORS; LITHIUM ION BATTERIES; UNIVERSAL 100-240 VAC POWER SUPPLY; 9.5 X 12 X 2 INCHES; COMES WITH CARRYING CASE; 0-50 C OPERATING TEMP |