NSN 4820-00-232-5469

Part Details | PRESSURE AND TEMPERATURE RELIEF VALVE

4820-00-232-5469 A valve designed to release under excessive pressure and/or excessive temperature by opening at a predetermined pressure and/or temperature. Thermostatically operated valves close when the pressure is relieved or the temperature is reduced. Fusible plug valves require replacement of the plug. See also VALVE, SAFETY RELIEF and VALVE, REGULATING. TEMPERATURE.

Alternate Parts: 10XL75210, 10XL4 75PSI34INCH, 10XL-4 75PSI-3/4INCH, 100XL4 75PSI34INCH, 100XL-4 75PSI-3/4INCH, 4820-00-232-5469, 00-232-5469, 4820002325469, 002325469

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
48OCT 24, 197000-232-546916996 ( VALVE, RELIEF, PRESSURE AND TEMPERATURE )
REFERENCE DRAWINGS & PICTURES

ANGLE GIVE "ADQM" AND "ADQN" ONLY IF FLANGED ONE OR TWO ENDS

SWIVEL NUT, FLARE

PLAIN

SWIVEL NUT, FLARE

PLAIN

SWIVEL NUT, FLARE

PLAIN

SWIVEL NUT, FLARE

PLAIN

Cross Reference | NSN 4820-00-232-5469
Part Number Cage Code Manufacturer
10XL7521079227WATTS REGULATOR CO
10XL-4 75PSI-3/4INCH79227WATTS REGULATOR CO
100XL-4 75PSI-3/4INCH79227WATTS REGULATOR CO
Technical Data | NSN 4820-00-232-5469
Characteristic Specifications
BODY STYLE ANGLE GIVE "ADQM" AND "ADQN" ONLY IF FLANGED ONE OR TWO ENDS
BODY MATERIAL BRASS
SEAT MATERIAL BRASS
FLOW CONTROL DEVICEG ANY ACCEPTABLE
FLOW CONTROL DEVICE MATERIAL BRASS
END CONNECTION QUANTITY2
FIRST END CONNECTION TYPE THREADED INTERNAL PIPE
FIRST END STYLE DESIGNATOR1 SWIVEL NUT, FLARE
FIRST END NOMINAL PIPE SIZE ACCOMMODATED0.750 INCHES
FIRST END THREAD DIRECTION RIGHT-HAND
SECOND END RELATIONSHIP WITH FIRST END NOT IDENTICAL
SECOND END CONNECTION TYPE THREADED EXTERNAL PIPE
SECOND END STYLE DESIGNATOR PLAIN
SECOND END NOMINAL PIPE SIZE ACCOMMODATED0.750 INCHES
SECOND END THREAD DIRECTION RIGHT-HAND
TEMP ADJUSTABILITY NOT ADJUSTABLE
MEDIA FOR WHICH DESIGNED WATER, FRESH
TEMP RATING210.0 DEG FAHRENHEIT
BULB LENGTH6.000 INCHES NOMINAL
BULB DIAMETER0.250 INCHES NOMINAL
TEMP CONTROL DEVICE TYPE THERMOSTATIC
OPENING PRESSURE SETTING75.0 POUNDS PER SQUARE INCH