NSN 4810-00-146-6162

Part Details | SOLENOID VALVE

4810-00-146-6162 A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.

Alternate Parts: 8262C13110VASC0, 8262C13-110VASC0, SAC335, 04F20C2114AAFGC05, 04F20C2114AAFGC05, 4810-00-146-6162, 00-146-6162, 4810001466162, 001466162

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
48SEP 24, 197100-146-616210998 ( VALVE, SOLENOID )
REFERENCE DRAWINGS & PICTURES

STRAIGHT THRU

Cross Reference | NSN 4810-00-146-6162
Part Number Cage Code Manufacturer
8262C13-110VASC004845AUTOMATIC SWITCH COMPANY
SAC33505477NEW SD INCSEATON-WILSON DIV
04F20C2114AAFGC0593781PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROL DIVISION
04F20C2114AAFGC0581978PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROLS DIVISION
Technical Data | NSN 4810-00-146-6162
Characteristic Specifications
STYLE DESIGNATOR STRAIGHT THRU
FLOW CONTROL DEVICE DISK
VALVE OPERATION METHOD SOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE110.0 AC
FREQUENCY IN HERTZ50.0
PHASE SINGLE
CURRENT RATING IN AMPS0.054
FLOW CONTROL DEVICE NORMAL OPERATION POSITION CLOSED
INLET/OUTLET OPERATING PRESSURE DIFFERENTIAL25.0 POUNDS PER SQUARE INCH MINIMUM AND 40.0 POUNDS PER SQUARE INCH MAXIMUM
APERTURE DIAMETER0.219 INCHES NOMINAL
MOUNTING POSITIONR$DVT