NSN 4730-00-216-1967

Part Details | SEDIMENT STRAINER ELEMENT

4730-00-216-1967 A replaceable device designed to remove solid particles from flowing liquids. The removal of particles is accomplished by porous material (metallic or non-metallic), wire mesh, perforated metal, or the like, constructed so the liquid can flow through the device while the solid particles are retained. It is designed to fit into a STRAINER, SEDIMENT (or similar cavity). It may have a reinforcement to prevent collapsing, distorting or rupturing. The degree of particles removed must be nominally rated at 50 microns, or more, or absolutely rated at 75 microns, or more. See also FILTER ELEMENT, FLUID.

Alternate Parts: 2062805700, 206-2805-700, 02062805725, 0206-2805-725, 2062805725, 206-2805-725, 4730-00-216-1967, 00-216-1967, 4730002161967, 002161967

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
47JAN 01, 196300-216-196718347 ( STRAINER ELEMENT, SEDIMENT )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL

Cross Reference | NSN 4730-00-216-1967
Part Number Cage Code Manufacturer
206-2805-70044503DATEX-OHMEDA INCDBA GE HEALTHCARE BIOSCIENCE
0206-2805-72544503DATEX-OHMEDA INCDBA GE HEALTHCARE BIOSCIENCE
206-2805-72544503DATEX-OHMEDA INCDBA GE HEALTHCARE BIOSCIENCE
Technical Data | NSN 4730-00-216-1967
Characteristic Specifications
MATERIAL COPPER ALLOY
FILTERING MEDIA DESIGN MESH
MESH SIZE40.0
WIRE DIAMETER0.01000 INCHES NOMINAL
STYLE DESIGNATOR CYLINDRICAL
LENGTH0.516 INCHES NOMINAL
ELEMENT OUTSIDE DIAMETER0.250 INCHES NOMINAL
SPECIAL FEATURESW/2 DRIVE SLOTS LOCATED 180 DEG APART ON FIRST END