NSN 4320-00-115-5084
Part Details | CENTRIFUGAL PUMP UNIT
4320-00-115-5084 An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.
Alternate Parts: W249686RH, W249686SH1, W249686SH1, W249686RH, W249686SH1, W249686RH, MILP18682, 4320-00-115-5084, 00-115-5084, 4320001155084, 001155084
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
43 | SEP 30, 1968 | 00-115-5084 | 17988 ( PUMP UNIT, CENTRIFUGAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4320-00-115-5084
Part Number | Cage Code | Manufacturer |
---|---|---|
W249686RH | 0UBG9 | CURTISS-WRIGHT ELECTRO-MECHANICALCORPORATION |
W249686SH1 | 88032 | CURTISS-WRIGHT ELECTRO-MECHANICALCORPORATION |
W249686SH1 | 0UBG9 | CURTISS-WRIGHT ELECTRO-MECHANICALCORPORATION |
W249686RH | 88032 | CURTISS-WRIGHT ELECTRO-MECHANICALCORPORATION |
W249686SH1 | 30760 | INGERSOLL RAND CO |
W249686RH | 30760 | INGERSOLL RAND CO |
MILP18682 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 4320-00-115-5084
Characteristic | Specifications |
---|---|
MAXIMUM DISCHARGE FLOW RATE | 5300.0 GALLONS PER MINUTE |
TOTAL HEAD | 43.000 FEET |
OPERATING SPEED AT RATED CAPACITY | 1185.0 REVOLUTIONS PER MINUTE |
PUMPING ELEMENT OPERATING POSITION | VERTICAL |
CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
STAGE QUANTITY | 1 |
MEDIA FOR WHICH DESIGNED | WATER, SALT |
FEATURES PROVIDED | SELF-PRIMING |
PUMP QUANTITY | 1 |
INTAKE CONNECTION QUANTITY | 1 |
INTAKE CONNECTION TYPE | ROUND FLANGE |
DISCHARGE CONNECTION QUANTITY | 1 |
DISCHARGE CONNECTION TYPE | ROUND FLANGE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
PRIME MOVER COOLING MEDIUM | AIR |
PRIME MOVER QUANTITY | 1 |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 440.0 |
FREQUENCY IN HERTZ | 60.0 |
PHASE | THREE |
CURRENT RATING IN AMPS | 92.0 |
INCLOSURE TYPE | FULLY INCLOSED |
ENVIRONMENTAL PROTECTION | DRIPPROOF |
COOLING METHOD | BLOWER COOLED |
NONDEFINITIVE SPEC/STD DATA | 111 TYPE |